Outdoor Air Conditioner
User's Information and Installation Instructions
13+ SEER Extra High Effi ciency Split System
These units have been designed and tested for
capacity and effi ciency in accordance with A.R.I.
Standards. Split System Air Conditioning units
are designed for use with a wide variety of fossil
fuel furnaces, electric furnaces, air handlers, and
evaporator coil combinations.
These instructions are primarily intended to
assist qualifi ed individuals experienced in the
proper installation of heating and/or air condi-
tioning appliances. Some local codes require
licensed installation/service personnel for this
type of equipment. Read all instructions carefully
before starting the installation.
USER'S INFORMATION
IMPORTANT
Read this owner information to become familiar
with the capabilities and use of your appliance.
Keep this with literature on other appliances
where you have easy access to it in the future.
FAN SWITCH
TEMPERATURE SCALES
If a problem occurs, check the instructions
and follow recommendations given. If these
suggestions don't eliminate your problem, call
your servicing contractor.
OPERATING INSTRUCTIONS
To Operate Your Air Conditioner for
Cooling —
1. Set the thermostat system switch to COOL
or AUTO and the thermostat fan switch to
AUTO. (See Figure 1)
2. Set the thermostat temperature to the
desired temperature level using the
temperature selector. Please refer to the
separate thermostat user's manual for
complete instructions regarding ther-
mostat programming. The outdoor unit
and indoor blower will both cycle on and
off to maintain the indoor temperature at
the desired cooling level.
SYSTEM SWITCH
Figure 1. Typical Thermostat
TEMPERATURE
SELECTOR

Advertisement

Table of Contents
loading

Summary of Contents for Nordyne 13+ SEER Extra High Effi ciency Split System

  • Page 1 Outdoor Air Conditioner User’s Information and Installation Instructions 13+ SEER Extra High Effi ciency Split System These units have been designed and tested for If a problem occurs, check the instructions capacity and effi ciency in accordance with A.R.I. and follow recommendations given. If these Standards.
  • Page 2: General Information

    To Operate Your Furnace for 1. Regularly: Heating — a. Clean or replace the indoor air fi lter at the start of each heating and cooling season, 1. Set the thermostat system switch to HEAT and when an accumulation of dust and dirt or AUTO and the thermostat fan switch to is visible on the air fi...
  • Page 3: Safety Considerations

    Condensing Unit Section — Each condens- ing unit is shipped with a refrigerant charge WARNING: adequate to operate the outdoor section with an indoor matching coil or air handler, and 15 Ensure all electrical power to the unit feet of refrigeration line. is off prior to installing or servicing the equipment.
  • Page 4: Installing The Indoor Unit

    not subject to erosion. The slab should be level ference between the indoor and outdoor sections and anchored (if necessary) prior to placing the should not exceed 20 feet. equipment on the slab. Filter Dryer Installation — A fi lter dryer is provided with PS series models only and must Cantilever Mount —...
  • Page 5: Functional Checkout

    the current provisions of the National Electrical temperature setpoint to its highest setting. Prior Code (ANSI/NFPA 70) and with applicable local to applying electrical power to the outdoor unit, codes having jurisdiction. ensure that the unit has been properly and securely grounded, and that power supply con- Thermostat Connections —...
  • Page 6 Comfort Alert Diagnostics (Select Models) TRIP LED (Red): indicates there is a demand — The Comfort Alert diagnostics is a break- signal from the thermostat but no current to the through innovation for troubleshooting heat compressor is detected by the module. The TRIP pump and air conditioning system failures.
  • Page 7: Adjustment Of Refrigerant Charge

    NOTE: Linesets over 15 feet in length may Listen for any unusual noises. If present, locate require additional refrigerant charge. NORDYNE and determine the source of the noise and cor- recommends 0.6 oz. of refrigerant per foot for rect as necessary.
  • Page 8 Status LED Description Status LED Troubleshooting Information Status LED Green “POWER” Module has power Supply voltage is present at module terminals 1. Compressor protector is open Red “TRIP” Thermostat demand signal 2. Outdoor unit power disconnect is open Y is present, but the 3.
  • Page 9 Miswired Module Indication Recommended Troubleshooting Action Green LED is not on, Determine if both R and C module terminals are module does not power up connected. Verify voltage is present at module’s R and C terminals. Review 24VAC Power W iring (page 4) for R and C wiring.
  • Page 10 Refrigerant Metering Device for 13 SEER Split System Air Conditioner with ZRKA Compressor Model Restrictor Bore System Charge Number Size (inches) R-22 (oz.) 1.5 ton 0.050 2.0 ton 0.059 2.5 ton 0.067 3.0 ton 0.075 3.5 ton 0.080 4.0 ton 0.089 5.0 ton 0.099...
  • Page 11 Restrictor Refrigerant Charging Charts Legend For Cooling Mode of Operation *Note all pressures are listed in psig. and all temperatures in deg. °F. - Shaded Boxes indicate fl ooded conditions - Rated Design Values. Suction Pressure will be lower than design value if indoor air fl ow, entering dry bulb, or entering wet bulb temperatures are lower than design.
  • Page 12 Restrictor Refrigerant Charging Charts with ZRKA Compressors Continued OUTDOOR TEMPERATURE (°F) 2-1/2 Suc. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Press. Press. Temp. Press. Temp. Press. Temp. Press. Temp. Press. Temp. Press.
  • Page 13 Restrictor Refrigerant Charging Charts with ZRKA Compressors Continued OUTDOOR TEMPERATURE (°F) Suc. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Press. Press. Temp. Press. Temp. Press. Temp. Press. Temp. Press. Temp. Press. Temp.
  • Page 14 Restrictor Refrigerant Charging Charts with CRK7 Compressors Continued 2-1/2 OUTDOOR TEMPERATURE (°F) Suction Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Press. Press. Temp. Press. Temp. Press. Temp. Press. Temp. Press. Temp. Press.
  • Page 15 TXV Refrigerant Charging Charts with ZRKA Compressors 1.5 Ton AC TXV Charging Chart Remove refrigerant when above curve Add refrigerant when below curve Liquid Temperature (F) 2.0 Ton AC TXV Charging Chart Remove refrigerant when above curve Add refrigerant when below curve Liquid Temperature (F)
  • Page 16 TXV Refrigerant Charging Charts with ZRKA Compressors Continued 2.5 Ton AC TXV Charging Chart Remove refrigerant when above curve Add refrigerant when below curve Liquid Temperature (F) 3.0 Ton AC TXV Charging Chart Remove refrigerant when above curve Add refrigerant when below curve Liquid Temperature (F)
  • Page 17 TXV Refrigerant Charging Charts with ZRKA Compressors Continued 3.5 Ton AC TXV Charging Chart Remove refrigerant when above curve Add refrigerant when below curve Liquid Temperature (F) 4.0 Ton AC TXV Charging Chart Remove refrigerant when above curve Add refrigerant when below curve Liquid Temperature (F)
  • Page 18 TXV Refrigerant Charging Charts with ZRKA Compressors Continued 5.0 Ton AC TXV Charging Chart Remove refrigerant when above curve Add refrigerant when below curve Liquid Temperature (F) TXV Refrigerant Charging Charts with CRK7 Compressors 2.0 Ton AC CRK7 TXV Charging Chart Remove refrigerant when above curve Add refrigerant when below curve Liquid Temperature (F)
  • Page 19 TXV Refrigerant Charging Charts with CRK7 Compressors Continued 2.5 Ton AC CRK7 TXV Charging Chart Remove refrigerant when above curve Add refrigerant when below curve Liquid Temperature (F) 3.0 Ton AC CRK7 TXV Charging Chart Remove refrigerant when above curve Add refrigerant when below curve Liquid Temperature (F)
  • Page 20 INSTALLER: PLEASE LEAVE THESE INSTALLATION INSTRUCTIONS WITH THE HOMEOWNER. 708451A (Replaces 7084510) ¢708451#¤ Specifi cations and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A. (01/06) 708451A...