Specifications — MHR-5STP-2 Cable
Specifications — MHR-5STP-2 Cable
Description
UL NEC/
C(UL) CEC
Part No. (length)
UL AWM
Model
Composite: (5) 26 AWG Miniature Coax • (2) 22 AWG Shielded Twisted Pairs • Coax Shielding: Aluminum Foil (100%) + Tinned Copper Serve
Nonplenum Cable • Gas-injected Foamed Polyolefin Insulation • PVC Inner Jackets • Gray PVC Outer Jacket
22-175-02 (500')
22-175-03 (1000')
MHR-5STP-2
NEC CM
UL 1581
CSA FT-4
Min. bend radius: 4.0"
Plenum Cable • Gas-injected Foamed FEP Insulation • Fluorocopolymer Inner Jackets • Blue Fire-resistant PVC Outer Jacket
22-181-02 (500')
22-181-03 (1000')
MHR-5STP-2P
NEC CMP
CSA FT-6
Min. bend radius: 7.0"
Standard
Shipping
No.
Lengths
Weights
of
Cond.
Ft.
m
Lbs. kg
Temp.
5
500
152.4
42
coax
1000
304.8
83
2
shielded
60 °C
twisted
pairs
Overall
cable
38
500 152.4
5
coax
1000 304.8
75
UL 910
2
shielded
60 °C
twisted
pairs
Conductor
Nominal
Shielding
Core OD
Materials
(stranding)
(% coverage)
Diameter
Nom. DCR
Inch
mm
Nom. DCR
26 AWG
0.072 1.83
Alum. Foil
19.1
(7/34)
(100%)
37.6
0.019"
Tinned Cu
0.48 mm,
Serve (95%)
Tinned Cu
12.2 ohms/
41 ohms/
1k ft,
40.0 ohms/
135 ohms
1 km
22 AWG
Alum. Foil
(7/30)
(100%)
0.030"
17 ohms/
0.76 mm,
Tinned Cu
56 ohms/
17 ohms/
1k ft,
56 ohms
1 km
17.2
26 AWG
0.074 1.88
Alum. in
(7/34)
Polyester Tape
34.0
0.019"
(100%)
0.48 mm,
Tinned Cu
Tinned Cu
Serve (95%)
41 ohms/
12.2 ohms/
1k ft,
135 ohms
40.0 ohms/
1 km
22 AWG
Alum. in
(7/30)
Polyester Foil
0.030"
(100%)
0.76 mm,
17 ohms/
Tinned Cu
56 ohms/
17 ohms/
1k ft,
56 ohms
1 km
Nominal
Nom.
Nom.
OD
Vel.
Imp.
of
(ohms)
Prop.
Inch
mm
75
81%
Single:
0.105
2.67
red, green, blue,
black, yellow
1k ft,
1 km
Sweep tested 5 MHz to 1 GHz.
Single:
66%
0.046
1.2
red and black,
green and white
1k ft,
1 km
Overall:
0.400
10.2
gray
Single:
75
81%
0.102
2.59
red, green, blue,
black, yellow
1k ft,
1 km
Sweep tested 5 MHz to 1 GHz.
Single:
66%
0.046
1.2
red and black,
green and white
with gray
1k ft,
fluorocopolymer
jacket
1 km
for each pair
Overall:
0.350
8.9
blue
Nominal
Nominal
Capacitance
Attenuation
dB/
dB/
MHz
pF/ft pF/m
100 ft
100 m
16.7
54.8
1
-0.5
-1.7
5
-1.2
-3.9
10
-1.7
-5.5
20
-2.4
-7.8
50
-3.8
-12.3
71
-4.5
-14.8
100
-5.4
-17.6
135
-6.3
-20.6
180
-7.3
-23.9
200
-7.7
-25.4
270
-9.1
-29.9
400
-11.5
-37.3
750
-16.4
-53.8
1000
-19.5
-64.0
3000
-43.6
-143.0
35
115
conductor-
conductor
62
203
conductor-
conductor,
connected to
shield
16.7
54.8
1
-0.5
-1.7
5
-1.2
-3.9
10
-1.7
-5.5
20
-2.4
-7.8
50
-3.8
-12.3
71
-4.5
-14.8
100
-5.4
-17.6
135
-6.3
-20.6
180
-7.3
-23.9
200
-7.7
-25.4
270
-9.1
-29.9
400
-11.5
-37.3
750
-16.4
-53.8
1000
-19.5
-64.0
3000
-43.6
-143.0
35
115
conductor-
conductor
62
203
conductor-
conductor,
connected to
shield
02 December, 2008
Need help?
Do you have a question about the MHR-5STP-2 and is the answer not in the manual?
Questions and answers