2.
3.
To wire through
top:
Mark a line distance "A" from the right of the centerline on the
underside of the cabinet. Mark the point on this line that is
2" (5.0 cm) from back wall. Drill a 11¼ '' (3.0 cm) diameter hole
through the cabinet at this point.
i
i
Centerline
I
I
11/4" ( 4.3cm)
from
Wall,
net cabinet
frame
A. 1015/16 ' '
(27.8
cm)
To wire through
wall:
Mark a line distance "A" from the left of the centerline on the
wall. Mark the point on this line that is 1" (2.5 cm) from the
bottom of the cabinet. Drill a 1V4" (3.0 cm) diameter hole
through the rear wall at this point.
I
Centerline
A.
101%6
'' (27.8
cm)
Style I - Cut Openings for 31/4" x 10" (8.3 cm x 25.4 cm)
Rectangular
Vent System
Roof Venting
To make a 41/4'' x 101/2 '' (10.8 cm x 26.7 cm) rectangular cutout
on the underside of cabinet top and bottom:
1. Mark lines 1/2"(1.2 cm) and 43/4"(12.1 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 51¼'' (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
4. Repeat steps 1-3 for the underside of the top of the cabinet.
Cabinet cutouts
....
(12.1 cm)
/
5114.
\
(13.3 cm)
*From wall, not cabinet frame
Wall Venting
To make a 31/2 '' x 101/2 '' (8.9 cm x 26.7 cm) rectangle in the
wall:
1. Make 2 lines by measuring 3/8"(0.9 cm) and 37/8"(9.8 cm)
down from underside of cabinet and mark on the centerline
on the back wall.
2. Mark lines 51¼ '' (13.3 cm) to the right and left of the centerline
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the
wall for the vent.
/
Centerline
I
Cabinet
I/
_Z___
T .........
_..........
i
I
37/8''
t
i
/
(9.8cm)
f
'
1
5¼"
51/4"
(13.3 cm)
(13.3 cm)
Style 2 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm)
Rectangular
Vent to Round Vent Transition
Roof Venting
To make a 41/4'' x 101/2 '' (10.8 cm x 26.7 cm) rectangular cutout
on the underside of cabinet bottom:
1. Mark lines 1/2"(1.2 cm) and 43/4"(12.1 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 51¼ '' (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
'12.1 cm)
/
51/4"
'1,
(13.3 cm)
*From wall, not cabinet frame
To make a circular vent opening on the underside of the
cabinet top:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line 5" (12.7 cm) from the back wall on the underside
of the top of cabinet.
3. Use a compass or a circle template to draw a circle with a
diameter that is 1¼,, ( 0.64 cm) larger than the vent.