A sturdy floor to support the total dryer weight of
200 Ibs (90.7 kg). The combined weight of a companion
appliance should also be considered.
=
A level floor with a maximum slope of 1" (2.5 cm) under entire
dryer. If slope is greater than 1" (2.5 cm), install Extended
Dryer Feet Kit, Part Number 279810. Clothes may not tumble
properly and automatic sensor cycles may not operate
correctly if dryer is not level.
=
For a garage installation, you will need to place the dryer at
least 18" (46 cm) above the floor. If using a pedestal, you will
need an additional 6" (15.24 cm).
Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation
clearances
a
The location must be large enough to fully open the dryer
door.
a
Additional spacing should be considered for ease of
installation and servicing.
a
Additional clearances might be required for wall, door and
floor moldings.
a
Additional spacing of 1" (2.5 ore) on all sides of the dryer is
recommended to reduce noise transfer.
a
Companion appliance spacing should also be considered.
Dryer Dimensions
(130,81 cm)
(96.52 cm)
"31½"
(80 cm)
27"
.._-_
(68.6 cm)
*
4
"
Most installations require a minimum 5½ (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Minimum installation spacing for custom undercounter
installation
The dimensions shown are for the minimum spacing allowed.
Custom undercounter
installation - Dryer only
00ml I
3B" min.
(96.52 cm)
O"
27"
O"
(Ocm)'-_(6B.8
cm)-_(O
cm)
Minimum installation spacing for recessed or closet
installation, with or without a pedestal
a
The dimensions shownare for the minimumspacing allowed,
a
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Closet installation - Dryer only
1o,,l_ 31½,,_1o"l
(0 cm) (B0 cm) (Ocm)
A
48 In.2
(310 cm:Z) -
24 In.2
(155 cm:Z) -
B
3"
_(7.6
cm)
3"
_-
(7.6 cm)
A. Side view - closet or confined area
B. Closet door with vents
Recessed or closet installation - Dryer on pedestal
o" -_ _-- 27" "--_ <-o"
o,,I I_- 31½"-_1o"I
(0 cm)
(68.6 cm)
(O cm)
(O cm)
(90 cm)
(0 cm)
A
B
A. Recessed area
B. Side view - closet or confined area