Connecting
Water Supply To Freezer
WATER SUPPLY
WARNING
To avoid electric shock, which can cause death or
severe personal injury, disconnect the freezer
from
electrical power
before connecting a water
supply llne
to the freezer.
_
CAUTION
*
Copper
or Stainless Steel braided
tubing is
recommended
for the water supply
line. Water
supply tubing
made of 1/4 inch plastic is not
recommended
to be used. Plastic tubing greatly
increases the potential
for water
leaks, and the
manufacturer
will not be responsible
for any damage
if plastic tubing
is used for the supply
line.
*
DO NOT install water
supply tubing in areas where
temperatures
fall below freezing.
*
Chemicals
from a malfunctioning
softener
can
damage
the ice maker. If the ice maker is connected
to soft water, ensure that the softener is maintained
and working
properly.
NOTE
Ensure that your water
supply line connections
comply
with all local plumbing
codes.
Before
Installing
The Water Supply Line, You Will Need:
"
Basic Tools: adjustable
wrench,
fiat-blade
screwdriver,
and Phillips
TM
screwdriver
*
Access to a household
cold water
line with water
pressure between
30 and 100 psi.
*
A water
supply line made of 1/4 inch (6.4 ram) OD,
copper
or stainless steel tubing.
To determine
the
length of tubing
needed,
measure the distance
from
the ice maker inlet valve at the back of the freezer
to your cold water
pipe. Then add approximately
7
feet (2.1 meters), so the freezer can be moved out for
cleaning
(as shown).
*
A shutoff valve to connect the water
supply line to
your household
water
system. DO NOT use a self-
piercing
type shutoff valve.
°
A compression
nut and ferrule (sleeve) for connecting
a copper
water
supply line to the ice maker inlet valve.
To Connect Water Supply Line To Ice Maker
Inlet Valve
1.
Disconnect
freezer
from electric
power source.
2.
Place end of water supply
line into sink or bucket.
Turn ON water
supply and flush supply line until
water
is clear. Turn OFF water supply at shutoff
valve.
3.
Remove plastic cap from water valve inlet and
discard
cap.
4.
If you use copper
tubing
- Slide brass compression
nut, then ferrule (sleeve) onto water
supply line.
Push water
supply line into water
valve
inlet as far
as it will go (1/4 inch / 6.4 mm). Slide ferrule
(sleeve)
into valve inlet and finger tighten
compression
nut
onto valve. Tighten another
half turn with a wrench;
DO NOT overtighten.
See Figure A.
g
_
Steel
Clamp
Brass
Compression
Clamp
gh
_
Ferrule
i
(Sleeve)
iubing
in loop to allow moving
pper
Waterline
freezer out for cleaning.
Water Valve
Bracket
Inlet
Water Valve
J
J
Copper Water Line
From Household Water Supply
Figure
A. Copper
Water
Line Connection
If you use stainless
steel
tubing
- The nut and
ferrule
are
already
assembled
on the tubing.
Slide
compression
nut onto
valve
inlet
and finger
tighten
compression
nut onto
valve.
Tighten
another
half
turn
with
a wrench;
DO
NOT
overtighten.
See Figure
B.
16