Changing the needle
Switch off the eectrica power
To remove: Lower the presser foot and
move the needle(s) to the highest position
by turning the handwheel. Push the needle
inserting tool (from the accessory box 56)
from below upward fully over the needle.
Loosen the fastening screw of the needle
(without removing it) with the
Allen key and pull the needle down to
remove.
To insert: Insert the needle into the hole E of
the needle inserting tool, so that the flat
needle shank K laces the flat side L of the in
serting tool. Now
insert
the needle fully into
the holder and tighten the fastening screws.
Remove the needle inserting tool.
Overlock needle types EL X 705, cat. no.
2002 are required for this machine.
I
13