Hotpoint RGA820 Owner's Manual & Installation Instructions page 27

20" and 24" compact gas ranges
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
F6]ADJUST THE OVEN BURNER AIR
SHUTTER IFNECESSARY (CONT.)
For LP Gas:
The flame should have approximately
1-inch
blue cones. After 30 seconds of burner
operation,
check for flames lifting off the
burner ports. If lifting is observed, gradually
reduce the air shutter opening until flames are
stabilized. Some yellow tipping
may be normal
for LP gas.
If Adjustment
is Necessary:
[_
Loosen the lock screw located at the top
of the air shutter, then rotate the air
shutter to the correct setting and
retiahten
screw.
Air shutter
Loosen
lock
screw
r-_ oven burner flame can be checked as
follows (without
burner baffle in place):
. To correct a yellow flame-Increase
size
of air shutter opening.
o To correct a lifting, but distinct, blue
flame--Decrease
size of air shutter
opening.
[_]
The air shutter should be set
approximately
2/3 open for natural gas,
and approximately
full open for LP gas.
F-D--] The oven burner air shutter adjustment
is
the same on ranges with a gas pilot or
electric ignition.
[_]
QUALITY
OF FLAMES
The combustion
quality of burner flames needs to
be determined
visually.
{A)Yellow flames:
Call for service
{B) Yellow tips on outer
cones:
Normal for LP gas
{C)Softblue flames:
Normal for natural gas
If burner flames look like (A),call for service. Normal
burner flames should look like (B) or (C), depending
on the type of gas you use.
With LP gas, some yellow tipping on outer cones is
normal
[-8] REPLACE
OVEN
PARTS
After all adjustments
are made, replace the
oven bottom, shelves and oven door.
27

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Rga824

Table of Contents