Exmark Lazer HP Operator's Manual page 32

Exmark zero turn riding mower operator's manual
Hide thumbs Also See for Lazer HP:
Table of Contents

Advertisement

e)
If the coolant level is low, remove the cap to the overflow bottle and fill to
the indicator line. Use coolant specified in Section 2.5.2.
NOTE: Units should only be filled with Dex-Cool© extended life coolant, which
can be identified by its orange color.
POTENTIAL HAZARD
♦ Engine coolant is hot and pressurized.
♦ Radiator and surrounding parts are hot.
WHAT CAN HAPPEN
♦ Spray or steam from hot, pressurized liquid in the
engine cooling system and touching a hot radiator may
cause severe burns.
HOW TO AVOID THE HAZARD
♦ Allow the engine to cool completely before removing
the radiator cap or servicing any component of the
cooling system.
POTENTIAL HAZARD
♦ Engine coolant is toxic.
WHAT CAN HAPPEN
♦ Swallowing coolant can cause poisoning.
HOW TO AVOID THE HAZARD
♦ Do not swallow
♦ Keep out of reach of children and pets.
5.1.3
Check battery charge:
Allowing batteries to stand for an extended period of time without recharging
them will result in reduced performance and service life. To preserve optimum
battery performance and life, recharge batteries in storage when the open
circuit voltage drops to 12.4 volts.
Note: To prevent damage due to freezing, battery should be fully charged
before putting away for winter storage.
a)
Check the voltage of the battery with a digital voltmeter. Locate the voltage
reading of the battery in the table below and charge the battery for the
recommended time interval to bring the charge up to a full charge of 12.6
volts or greater.
IMPORTANT: Make sure the negative battery cables are disconnected
and the battery charger used for charging the battery has an output of 16
volts and 7 amps or less to avoid damaging the battery (see chart below for
recommended charger settings).
Voltage
Reading
12.6 or greater
12.4 – 12.6
12.2 – 12.4
12.0 – 12.2
11.7 – 12.0
11.7 or less
WARNING
CAUTION
Service Interval: Monthly
Percent
Charge
Charger Settings
100%
16 volts/7 amps
75 – 100%
16 volts/7 amps
50 – 75%
16 volts/7 amps
25 – 50%
14.4 volts/4 amps
0 – 25%
14.4 volts/4 amps
0%
14.4 volts/2 amps
- 27 -
Maximum
Charging Interval
No Charging Required
30 Minutes
1 Hour
2 Hours
3 Hours
6 Hours or More

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lazer z

Table of Contents

Save PDF