About The Auto Setup; Speaker Detection; Measurement - Denon AVR-589 Owner's Manual

Hide thumbs Also See for AVR-589:
Table of Contents

Advertisement

* Do not disconnect
the setup
microphone
until the auto setup
procedure
is completed.
*When
using headphones,
unplug the headphones
before starting
the auto setup procedure.
* Loud test sounds may be played during Audyssey MultEQ automatic
speaker setup. This is part of normal operation.
If there is background
noise in room, these test signals will increase in volume.
* Do not stand between the speakers and setup microphone
or allow
obstacles
in the path while the measurements
are being made. This
will cause inaccurate readings.
* Make the room as quiet as possible. Background
noise can disrupt
the room
measurements.
Close windows,
silence
cell phones,
televisions,
radios,
air
conditioners,
fluorescent
lights,
home
appliances,
light dimmers, or other devices as measurements
may
be affected by these sounds.
Cell phones should be placed away from all audio electronics
during
the measurement
process
as Radio Frequency
Interference
(RFI)
may cause measurement
disruptions
(even if the cell phone is not in
use).
* Operating
MASTER V0[[JME
during the measurements
will cancel
the measurements.
About the Auto Setu
The Audyssey
MultEQ auto setup function
detects
the presence of
each speaker and automatically
calculates the speaker size, channel
level, distance, and optimal
crossover
frequency
setting.
Audyssey
MultEQ corrects acoustical distortions within the listening area.
Before starting, connect and position all of your speakers.
Once started,
MultEQ will play a series of test tones through each
speaker.
If an error message appears during the measurements,
check "Error
Messages",
take the advised action, then start the measurements
again (_page
19).
Step1
: Speaker Detection
The
speaker
connection
and polarity
are detected
at the first
measurement
position
(main
listening
position).
The
following
attributes
are also determined
at this time: "Speaker Size", "Speaker
Distance",
"Channel Level",
"Crossover
Frequency".
0} Press <] while "Auto Set<Start"
is displayed.
*While
the measurements
are being conducted
"Measure:FL
<Ccl" ("FL" indicates the speaker being measured) is displayed.
*When
the measurements
are completed,
speaker
detection
check is displayed.
Example : For a 5.1 channel speaker configuration
Yes: ".1"
No:"0"
........ Number of surround speakers
...........
Number of front speakers or
center speakers
* To cancel the measurements,
press <] while "Measure:FL
<Ccl"
is displayed ("Ccl" stands for "Cancel").
* If the result differs from the actual connection
status or an error
message appears, use V to display "Retry<"
and then press <] to
repeat the measurement.
* If the result still differs from the actual connection
status after re-
measurement
or the error message still appears, it is possible that
the speakers are not connected properly. Turn the AVR-S89 off, check
the speaker connections
and repeat the measurement
process from
the beginning.
Do not change the speaker connections
or subwoofer
volume
after
"Step 1"
Step 2 : Measurement
0} Press V to select "2nd Start<",
then press <::].
* The measurement
of the 2nd position starts.
Move the microphone
to the 3rd position and press <].
* The measurement
of the 3rd position starts.
(_ Perform _ repeatedly.
* "Calculate<"
is
displayed
when
you
have
completed
measurements
in 6 positions.
* If you want to stop after measuring just five or fewer positions,
use V to display "Calculate<".
After completing
a measurement
position, move the microphone
to
the next position.
Measure
at 6 positions:
the main listening
position
and 5 other
surrounding positions. Although
it is allowable to measure less than 6
positions, it is recommended
to measure 6 for best results.
Step 3 : Calculation
The values
obtained
from
the measurements
are automatically
analyzed and the attributes
for each of the speakers in the listening
area are determined.
0_ Press <] while "Calculate"
is displayed.
* "Calculating"
is displayed and analysis begins.
* Analysis takes several minutes to complete.
*The
time
required for this analysis
depends
on the number
of
speakers connected. The greater the number of speakers connected,
the longer analysis will take.
Do not change
the speaker
connections
or subwoofer
volume,
or speaker locations
after making
measurements.
If changes
are
necessary,
make the changes and use the Audyssey
MultEQ auto
setup once again for an updated EQ solution.
18