Installation Checklist; Chassis Installation - Friedrich PTAC Series Installation & Operation Manual

Packaged terminal air conditioners & heat pumps
Hide thumbs Also See for PTAC Series:
Table of Contents

Advertisement

920-087-04
(8-05)
Installation Checklist
[]
Inspect all components and accessories for damage
before and after installation.
[]
Remove the cardboard wall sleeve support and grille
weatherboard.
[]
Check for proper wall sleeve installation in accordance
with the wall sleeve installation instructions.
[]
Check for a subbase kit or other means of structural
support which is required for ALL installations projecting
more than 8" into room.
[]
Install the recommended Condensate Drain Kits for
complete condensate removal.
[]
Ensure that the chassis is installed in a 16" high x 42" wide
wall sleeve that is no deeper than 13 3/4". A baffle kit is
required if the sleeve exceeds that depth.
[]
Ensure that drapes, bed, bedspread, furniture, etc. DO
NOT block either return or discharge air grilles.
[]
Inspect the condenser air inlet and outlet for any
obstructions (shrubbery, etc.)
[]
Ensure that'reset' button is pressed on LCD device (only
on cord connected models)
Section III - ChassisInstallation
Checkto be surethewall sleeve,extension(if used),grille,anddrain kit are installedproperly beforechas., i sinstallation.
1. Removetheweatherboardand centersupportfrom the sleeve
(if still in place). Be sure an outdoor grille is attached.
Wall sleeve
NOTE: To avoid breaking the door or hinge pins, do not apply
excessive force when installing
®
Pins
--Weatherboard
Center support
IMPORTANT:Usea wall sleeveadapterkit (PXSE)if
installing a P-Series chassis in a T-Series sleeve.
Suffocation hazard
Keep bag away from babies and children.
Do NOT use in cribs, beds or playpens. Destroy
immediately after opening. This bag is NOT a toy.
Failure to do so can result in personal injury and/or death
"
Control
Door
i
J
Front Panel
3. Remove the two chassis shipping brackets from the ends
of the shipping pallet.
®
Compressor
Chassis
shipping bracket
Shipping pallet
2. Remove the front cover contained in a protective plastic bag
from chassis. Remove the bag and dispose of it properly.
If the control door is not installed, follow these steps:
From the front of the cover, slide the right control door pin
into the hole on the right side of the front cover. Slide the
left door pin into the hole on the left side of the front cover
opening and snap it into place.
14
IMPORTANT: When installing a Friedrich P-Series PTAC intoan
existing sleeve, it is important to ensure that the unit is installed
completely. Inspection of the air seal between the condenser air
baffles and around the indoor mounting flange is recommended.
In some cases additional gaskets or baffling may be required.