Any changes or modifications to the unit not expressly approved by ALTINEX, Inc. could void the user’s authority to operate the equipment. cause undesired MULTI-TASKER™...
ABOUT YOUR MULTI-TASKER™ MT104-108 6-in 1-out S-Video Switcher Card The MT104-108 is a 6-in (+1 internal input) 1-out S-Video Switcher Card designed for use in Multi-Tasker enclosures. The MT S-Video SW card enables 6 S-Video sources to be connected and switched to a single display or recording device.
INSTALLING YOUR MULTI-TASKER™ Step 1. Slide the MT104-108 into an available slot in the Multi-Tasker™ Enclosure in order to connect to the bus. Make sure that the MT104-108 card fits into place. Secure the card to the Multi-Tasker™ by tightening the retainer screws located on the top and bottom of the MT104-108 card.
Page 8
Example: One MT104-108 card is in slot #2 of unit 3: Send the command [VERC2U3] and the Multi-Tasker™ Enclosure will return: MT104-108 690-0160-002 MT104-108 = card type 690-0160-002= software version 2. [C] This command receives the status of the card. Command Format: [CnUi] Cn = card ID (n = # from 1 to max slots) Ui = unit ID (i = from 0 to 9) ( refer to the...
Page 9
Example: There are two MT104-108 cards in slots 6 and 7 of unit 3. Enable input 1 of card 6 and input 3 of card 7 simultaneously. commands: [ON1C6U3P] [ON3C7U3P] [SW] If "F" is included, use the [ONmCnUiPF] command or the [ONmCnUiFP] command. [ON…..F]: feedback After processing a command, an OK or ER will be returned as feedback if "F"...
Page 10
6. […S] – Save This command will save the configuration command being sent in memory. sending the command [ON1C4S], after reset or power up, output 1 on C4 will be enabled. 7. […F] – Feedback After processing a command, an OK or ER will be returned as feedback if "F"...
[G1]: will return feedback as ON12 G1U0. [G2]: will return feedback as ON2 G2U0. 14. [RD] This command displays the members in each group. Command Format: [RDGkUi] = group number (k = # from 1-9) = unit number (i = # from 0-9) member = C1 - C19 (card 1 to max cards) Example: The cards in slots 1, 2 and 19 are part of group...
LED lights, the problem is the card cage slot. The card cage may require service. Call ALTINEX at (714) 990-2300. If the other slots do not work and the LED is still not lit, see Solution 2.
Need help?
Do you have a question about the MULTI-TASKER MT104-108 and is the answer not in the manual?
Questions and answers