We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers throughout the world. This manual covers: MX2206RM – 6 – in, 1 - out RGBS Auto Switcher SWITCHERS TABLE OF CONTENTS PRECAUTIONS / SAFETY WARNINGS ...2 GENERAL ...
Please read this manual carefully before using your MX2206RM Switcher. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your MX2206RM and to prevent fire and shock hazard. Please read them carefully and heed all warnings.
ABOUT YOUR SWITCHER The MX2206RM is a 6-in 1-out solid rate RGBS switcher with auto-switching and Sync Delay Switching capabilities. It can be controlled using its built-in front panel, through RS-232, or through the use of contact closures. Contact closure control requires the use of an optional adapter, part #RC5204CC.
Press & hold Input 3, Power ON 2.0 second delay Press & hold Input 4, Power ON The factory default setting for the MX2206RM is 0 delay. To reset the unit to this default, input 1 must be pressed and held during the power up sequence.
A maximum of four switchers can be connected in this configuration. 4.10 POWER SUPPLY The MX2206RM Switcher has 5V power supply available on pin 8 of the 9-pin “D” connector. This voltage can be used to drive external circuits or as a pull up voltage for open collector type outputs.
If you experience any problems, please call 1-800-258-4623 or 1-714-990-2300 for international calls. OPERATION 7.1 RS-232 CONTROL The MX2206RM Switcher uses a female 9-pin HD connector on its rear panel that allows access to a variety of control capabilities. computer 9-pin D connector...
IBM PIN No. MX2206RM PIN No. Connection of IBM-PC 9-pin D to MX2206RM 9-pin D. Note: 4, 6, 8 shorted together in IBM side only. Port setting preferences for the control system or computer being used to control the switcher should...
This command is designed to allow the MX2206RM Switcher to program each of the inputs to respond to a selected range of input commands. For example, if command [SET10104] is issued, then the following commands will select only Input 1: [I01O01], [I02O01], [I03O01], [I04O01]. In other words a range of I/O commands can address the same input.
MX2206RM are connected together to form a single switcher. When the input channel button is pressed the loop control pin is internally grounded and the MX2206RM Switcher selects INPUT 4 as the default input. In this configuration the loop control pin 6 on the 9 pin D connector is connected to the same pin on all switchers.
LED lights flash. This is does not designed to avoid accidental respond? resetting. Can the The MX2206RM can be rack MX2206RM mounted by itself or two units be rack side by side. The width of the mounted? unit is 1/2 rack wide. Altinex...
Make sure that cable is made according to manual, where RX pin of the MX2206RM is connected to TX pin of the computer. If you are controlling the unit by RS-232 command, make sure there is minimum delay of 100 milliseconds before sending the next command.
In the unlikely event that an Altinex product needs to be returned please follow the policies below: Altinex will accept product returns for a period of 30 days from authorized Altinex dealers. Products must be returned in an unopened package.