Download Print this page

Craftsman 919.167461 Owner's Manual page 19

Permanently lubricated single stage side stack air compressor
Hide thumbs Also See for 919.167461:

Advertisement

Available languages

Available languages

In nl - - [ oll_'-]
_[oIo]nJJP,[_
_
Performing repairs may expose voltage sources, moving
parts or compressed
air sources, moving parts or com-
pressed air sources. Personal injury may occur. Prior to attempting any
repairs, unplug the air compressor and bleed off all air tank air pressure.
PROBLEM
CAUSE
CORRECTION
Excessive tank
pressure - safe-
ty valve pops
off.
Air leaks at
fittings.
Air leaks at or
inside check
valve.
Air leaks at
pressure switch
release valve.
(if equipped)
Air leaks in air
tank or at air
tank welds.
Air leaks
between head
and valve plate.
Pressure switch does not
shut off motor when com-
3ressor reaches "cut-out"
pressure.
Pressure switch "cut-out"
too high.
Tube fittings are not tight
enough.
Check valve seat damaged.
Defective pressure switch
release valve.
Defective air tank.
Leaking seal.
Move On/Auto/Off
lever to
the "OFF" position,
if the
unit does
not shut off contact a
Trained Service Technician.
Contact a Trained Service
Technician.
Tighten fittings where air can
be heard escaping. Check
fittings with soapy water
solution. DO NOT OVER-
TIGHTEN.
A defective check valve
results in a constant air leak
at the pressure release valve
when there is pressure in the
tank and the compressor
is
shut off. Replace check
valve. Refer the "To Replace
or Clean Check Valve" in the
"Service and Adjustment"
section.
Contact a Trained Service
Technician.
Air tank must be replaced.
Do not repair the leak.
Do not
drill into,
weld or otherwise modify
air tank or it will weaken.
The tank can rupture or
explode.
Contact a Trained Service
Technician.
19_ ENG
D28071

Advertisement

loading