Safety Guidelines
Assembly
Operation
Maintenance
Service
and Adjustments
Troubleshooting
Repair
Parts
CAUTION:
Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sears,
Roebuck
and Co., Hoffman
Estates,
IL 60179
U.S.A.
Visit our Craftsman website: www.sears.com/craftsman
D27312
Rev3
8/15/03

Advertisement

loading

Summary of Contents for Craftsman 919.167311

  • Page 1 Operation • Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman D27312 Rev3 8/15/03...
  • Page 2 HOW TO ORDER REPAIR PARTS ...... back cover ltl__1 ;| ;[_I_ hi" FULL ONE YEAR WARRANTY AIR COMPRESSOR If this CRAFTSMAN Air Compressor fails due to a defect in material or workmanship within one year from the date of purchase, Sears will at its option repair or replace it free of charge.
  • Page 3 -"1 ".,1 =[e]I _1 [_,__1 II[o] _ I[e] -"_',__ t,tl Model No. 919_167311 Max. Developed Bore 2.38" Stroke 1.35" Voltage-Single Phase 120V/60HZ/1 PH Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig [-.'Y.,I _1 _ I_'d[€-lJ] Im]=1 IqI_I ::_'_.,I m] : :1 _11 _1i II[e _]_._...
  • Page 4 I1_I_o];]lL"_ +Ill [,,'9'-'I _1 _ i'dl I +F,,,_11_o _+]L_,[,,I Save these instructions improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. ,I;1"1.,I;I n WARNING: Risk of explosion or fire How To Prevent It What Could Happen...
  • Page 5: Accessories

    WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. How To Prevent It What Could Happen Failure to properly drain Drain tank daily or after each use.
  • Page 6 WARNING: Risk of Electrical Shock WHAT CAN HAPPEN HOW TO PREVENT IT Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions, powered device, If it is not used properly Never operate compressor with it may cause electric shock.
  • Page 7 WARNING: RISK OF BURNS WHAT CAN HAPPEN HOW TO PREVENT IT Touching exposed metal such as the Never touch any exposed metal parts on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns, hot for several minutes after operation.
  • Page 8 WARNING: RISK OF UNSAFE OPERATION WHAT CAN HAPPEN HOW TO PREVENT IT Review and understand all instructions Unsafe operation of your air compressor and warnings in this manual. could lead to serious injury or death to Become familiar with the operation and you or others, controls of the air compressor.
  • Page 9: Duty Cycle

    Become familiar with these terms When the tank pressure drops to a certain low level the motor will restart before operating the unit. automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
  • Page 10: Assembly

    Assemble Wheels Contents of Carton 1 - Air Compressor It will be necessary to brace or support Wheels one side of the air compressor when installing the wheels because 2 - Shoulder Bolts, 3/8-16 the compressor will have a Hex Nuts, 3/8-16 tendency to tip.
  • Page 11: Installation

    I I_[-.'_1 Iv;_ II Ir;'ul[o_J HOW TO SET UP YOUR This plug MUST be used with a grounded outlet. UNIT IMPORTANT: The outlet being used Location of the Air Compressor must be installed and grounded in accordance with all local codes and Locate the air compressor in a clean, ordinances.
  • Page 12: Operation

    Extension Cords Voltage and Circuit Protection Refer to the Parts Manual for the Using extension cords is not recommended. The use of extension voltage and minimum branch circuit cords will cause voltage to drop requirements. resulting in power loss to the motor Risk of Unsafe and overheating.
  • Page 13 Know Your Air Compressor READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Pressure Tank Pressure Gauge Outlet Switch Pressure...
  • Page 14 Motor Overload Protector: The Air Compressor Pump (not shown): Compresses air into the air tank. motor has an automatic reset thermal Working air is not available until the overload protector. If the motor compressor has raised the air tank overheats for any reason, the pressure above that required at the overload protector will shut off the air outlet.
  • Page 15 Move the On/Auto/Off lever to How to Start: "ON/AUTO" position. The Turn the On/Auto/Off lever to compressor will start. "AUTO" and allow tank pressure Run the compressor for 15 to build. Motor will stop when minutes. Make sure the drain tank pressure reaches "cut-out"...
  • Page 16: Maintenance

    Customer Responsibilities Before Daily ol after Every Every aach each Yearly hours _ours Check Safety Valve • Drain Tank • Air Filter 0(1) • Air compressor pump intake and exhaust valves • 1- more frequent in dusty or humid conditions To Check Safety Valve...
  • Page 17 After the water has been drained, IMPORTANT: Do not operate the close the drain valve (clockwise). compressor with the air filter removed. The air compressor can now be stored. If dirty, rinse air filter with warm NOTE: If drain valve is plugged, water and squeeze dry.
  • Page 18 All maintenance and repair Unscrew the check valve (turn operations not listed must be counterclockwise) using a 7/8" open end wrench. Note the performed by Trained Service orientation for reassembly. Technician. Using a screwdriver, carefully push the valve disc up and Risk of Unsafe down.
  • Page 19 Assemble the regulator and To Replace Regulator orient as shown. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section. Unplug compressor. Remove the outlet pressure gauge and quick connect (if equipped) from the regulator. Remove the regulator.
  • Page 20 Before you store the air compressor, Risk of Bursting. Water will make sure you do the following: condense in the air tank. If not Review the "Maintenance" drained, water will corrode and section on the preceding pages weaken the air tank causing a risk and perform scheduled of air tank rupture.
  • Page 21: Service And Adjustments

    d:{ollJ :] il ::F,."] -" [oIo]l III _[I Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
  • Page 22 PROBLEM CAUSE CORRECTION Pressure reading It is normal for "some" If there is an excessive on the regulated )ressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the...
  • Page 23 PROBLEM CAUSE CORRECTION Regulator will Damaged regulator. Replace. not shut off air outlet. Motor will not Let motor cool off and Motor overload protection run. overload switch will switch has tripped. automatically reset. Motor will start automatically Tank pressure exceeds pressure switch "cut-in"...
  • Page 24 ._ I-'I_o]_V_l *_ -'! _o) -II m] ¥,__:_,__ Air Compressor Model Number 919.167311 1Torque 15-25 In*Lbs Torque 100_120 imLbs 9-12 Ft*Lbs Torque D27312 24_ENG...
  • Page 25 Nut Sleeve Assembly 3/8" AC-0774 Isolator (3) A0-0292 Outlet Tube SSP-7821-1 Nut Tubing 3/8" OD SSG-3105 O-Ring Pump Assembly LA-3069 Label, Craftsman LA-3027 Label, Drain Tank Eng/Spa LA-3108 Label, Hot Surface SST-107 Recess Rubber Bumper (2) SSF-630 Screw (2) D23565 Label, Star Rating D23138 Wheel 9"...
  • Page 26 Air Compressor Model Number 919.167311 Torque 7-10 Ft-Lbs The picture shown is for reference only. It may differ from actual unit, . i% o oo01-03'o-Lbs Torque 42-48 In-Lbs Torque 100-120 In-Lbs Torque 100-120 tn-Lbs D27312 26_ ENG...
  • Page 27 Air Compressor Model Number 919.167311 PART NUMBER DESCRIPTION SSF-586 Screw 1/4-20 UNC x .75 AC-9198 SSF-615 Screw 1/4-20 UNC-2A Z-AC-0140 Eccentric Bearing Z-D26712 Motor DAC-161 Shim >x 78 Cylinder Sleeve >x79 Connecting Rod Assembly >x79-2 CAC-248-2 Formed Compression Ring > 79-3 ACG-29 Connecting >x79-4...
  • Page 28: Notes/Notas

    GARANT|A TOTAL DE UN AI_IO DEL COMPRESOR DE AIRE Si este compresor de aire Craftsman fallase debido a defectos de materiales o de fabricaci6n dentro del aSo de su fecha de compra, Sears, a su opci6n, Io reparar& o reemplazar& sin costo alguno.
  • Page 29 Modelo N ° 919-167311 Max. HP desarrollado Di&metro interior 2,38 po (60,4mm) Carrera 1,35 po (34,3mm) Tensi6n monofasica 120V/60HZ/1 PH Circuito mfnimo requerido Tipo de fusibleAcci6n retardada Capacidad de aire en el tanque 30 Galones (113,6 Iitros) Presi6n de corte de entrada Presi6n de corte de salida SCFM a 40 psig 8,6 Calibre de libras...
  • Page 30 _lJ_[-:'jlj;1E_o,][o_"] VlhVd,_T_o]--]nL,_hnl_ Im]::l_UJ-']lmT.,_m] GUARDE ESTAS INSTRUCCIONES La operaci6n o el mantenimiento inadecuados de este producto podrian ocasionar serias lesiones y da6os a la propiedad. Lea y comprenda todas las advertencias instrucciones de funcionamiento antes de utilizar este equipo. ".l::ll[_ ;{, ADVERTENCIA: Riesgo de Explosi6n...
  • Page 31 •,,,] ::1 al [ _ r,{o ADVERTENCIA: Riesgo de Explosibn las siguientes condiciones poddan, ¢ausar el debi]itamiento del tanque, determinar su explosi6n violenta, da_os a la propiedad o serias lesiones. qud puede occurrir cbmo prevenirlo Drenaje inadecuado del agua condensada Drene el tanque diariamente o despu_s...
  • Page 32 ADVERTENCIA: Riesgo de choque eldctrico qud puede occurtir c6mo prevenirlo Su compresor de aire est_ 8ccionado Jam&$ opere eI compresor a la intemperie electricidad, Como cua_quier otto dispositivo cuando est_ IIov+endo o en condic+ones de el_ctrico imputsado el_ctricamente, si no se Io humedad, utiliza adecuadamente, podrla causarle...
  • Page 33 ADVERTENCIA: Riesgo de Quemaduras qu_ puede occurrir cdmo prevenido Jam&s toque partes de metal expuestas en el Tocar el metal expuesto tal como el cabez83 compresor durante o inmediatamente despu_s del compresor o los tubos de salida del de la operaci6n, el compresor permanecer_ escape_ puede ocasionarle...
  • Page 34 ',1=1! [ _ ;{_ ADVERTENCIA: Riesgo de Serias Lesiones o Da_os a la Propiedad Transpottar el Compresor (Fuego, inhalaci6n, da_o a la superficie de vehiculos) qud puede occutrit cbmo prevenirlo El aceite puede derramarse y ello podfia Deposite el compresor sobre una alfombrilla resu{tar en serias lesiones o la muerte debido protectora...
  • Page 35 Ptesibn minima de corte: Cuando el Familiarfcese con los siguiantes t_rminos, motor est& apagado, la presiSn del tanque antes de oparar la unidad: de elre baja a medida que usted contint_a CFM: (Cubic feet per minute) Pies cQbicos usando su accesorio< Cuando la presi6n pot minuto.
  • Page 36 Ensamble de las ruedas Contenido de la caja 1- Compresor de aire 2- Ruedas del equipo cuando se instalan las ruedas porque el compresor tenderd 2- Pernos con resalto, 3/8" - 16 voltearse. 2- Tuercas hexagenales, 3/8" - 16 Fije las ruedas con pemos con 2- Parachoques de goma resalto y tuercas come se muestr&...
  • Page 37 COMO PREPARAR LA UNIDAD AsegOrese de que el tomaconie_te que sera utilizado tenga la misma con&:juraci6n que el enchufe de conexi6n Ubicacibn del comp_sor de aire a tierra. Ubique al compresor de aire en una zona NO UTILICE UN ADAPTADOR. Ver Iimpia, seca y bien ventilada.
  • Page 38 Cables de extensibn eldctrica Proteccibn del voltaje y del circuito No se recomienda la utilizaci6n de cables Acerca del voltaje y la minima cantidad de de extensi6n el6ctrica. El uso de cables circuitos requeridos, refierase al cuadro de extensi6n el6ctrica originar& una caida de especificaeiones.
  • Page 39 Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraalones contra su unidad a fin de familiarizarse con la ubicaci6n de los distintos controles y regulaalones. Conserve este manual para referencias futuras.
  • Page 40 autom&ticamente una vez enfriado el motor< Bomba de compresibn del aire (no mostrada): Comprime el aire dentro del Si el protector de sobrecarga apaga el tanque. El elre de trabajo no se encueotra motor con mucha frecuencia, vetiflque si disponible hasta que el compresor haya hay algt_n pesible problema de veltaje.
  • Page 41 Luego de 15 minutos, cierre la valvula de Cbmo poner en marcha: drenaje (sentido horario). El aire recibido Mueva la palanca On/Auto/Off a 3a it& Ilenando hasta el punto de "corte" de posici6n "AUTO" y deje que se presi6n, y el motor se detendr& incramente la presi6n del tanque.
  • Page 42 Responsabilidades del cliente Antes Diadanente Cads Cads Anualmente de cada e luege de cads use tJso horas horas Verifique la v&lvula de seguridad Drenaje de{ tanque O(1) • Filtro de sire Valvulas de entrada y escape de la bombs del compresor de sire 1- M&s frecuente en condiciones...
  • Page 43 Una vez drenada el ague, cierre tMPORTANTE: No opere el compresor sin el filtro de aire. valvula de drenaje (girando an sentido horatio). Ahora el eompresor Si est& sucio enjuague el filtro de aire de aire podr& sat guardado. con agua tibia y expdmalo hasta que NOTA: Si [a v&lvula de drenaje fuera del seque.
  • Page 44 Desenresque la valvule de retenci6n TODO TIPO DE MANTENIMIENTO OPERACIONES DE REPARACION NO girandole hecia la izquierda usando una Ilave de boca de 7/8 plug. MENCIONADOS_ DEBEP_N SER EFECTUADOS POR PERSONAL TI_CNICO (22 ram). Tome note de la orientacion para volveda a ESPECIALIZADO.
  • Page 45 Ensamble el regulador y orientelo de Para reemplazar el regulador Libere toda la presi6n del aire del tanque. Yea "Drenaje del tanque" en la secci6n "Mantenimiento". 2< Desenchufe el equipo. 3< Usando una Ilave de tuercas ajustable retire el medidor de salida de presion y la conexioN rapida del regulador la tiene)<...
  • Page 46 Antes de guerdar su compresor de aire, Riesgo de Explosibn, El asegQrese de hacer Io siguiente: agua se condensa dentro del tanque de Revise la secci6n "Mantenimiento" aire, Si no se dtene, ella cotroerd de las paginas preeedentes y ejeeute debilitando la paredes del tenque de el mantenimiento...
  • Page 47 [_l_.,_ Im] _ I m] p ';l_] Z [T_--]lli[o,,[o] I m] " _ I _ :To]=]nil : 4i_Y;%,."] Riesgo de Operacibn Insegura: La unidad arranca automaticamente cuando esta enchufada. AI hacer el mantenimiento, el operador puede quedar expuesto a fuentes de corriente de aire comprimido o a piezas...
  • Page 48 PROBLEMA CORRECCI6N CAUSA Si habiese una caida excesiva de La lectura de la ESnormal que ocurra algQn presi6n durante el uso del descenso en la presi6n. presi6n sobre an accesorio, ajaste el regulador man6metro acuerdo a las instrucciones de la viene equipado secci6n Operaci6n.
  • Page 49 CAUSA CORRECCI(_N PROBLEMA El motor no El interruptor de protecci6n Deje enfriar el motor y el funciona. interruptor de sobrecarga se obrecarga del motor se ha abierto< reajustar& autom&ticamente El motor arrancar& automaticamente La presi6n del tanque excede la presion de "corte maximo" cuando la presi6n del tanque caiga For debajo de la presi6n de corte del interruptor...
  • Page 50 D27312 50 -SP...
  • Page 51: Repair Protection Agreements

    Protection Agreements Reparaciones Congratulations on making a smart Felicitaciones per hater una compra purchase. Your new Craftsman <"_ p roduct is inteligente. Su nueva unidad Craftsman _) est& designed and manufactured for years of diseSada y fabricada pars aSos de operaci6n dependable operation.