Download Print this page

Craftsman 919.167461 Owner's Manual page 15

Permanently lubricated single stage side stack air compressor
Hide thumbs Also See for 919.167461:

Advertisement

Available languages

Available languages

Customer Responsibilities
Check Safety Valve
Drain Tank
Air Filter
Air compressor pump intake
and exhaust valves
Before
Daily
ol
_ach
a_er
each
use
use
F_quently
• (1)
1- more frequent in dusty or humid conditions
Yearly
I_
Unit cycles auto-
matically when
power is on. When performing
maintenance,
you may be exposed
to voltage sources, compressed
air, or moving parts. Personal
injuries can occur. Before perform-
ing any maintenance
or repair, dis-
connect power source from the
compressor and bleed off all air
pressure.
To ensure efficient operation and
longer life of the air compressor unit,
a routine maintenance schedule
should be prepared and followed.
The following routine maintenance
schedule is geared to an unit in a
normal working environment operat-
ing on a daily basis. If necessary, the
schedule should be modified to suit
the conditions
under which your
compressor
is used. The modifica-
tions will depend upon the hours of
operation and the working environ-
ment. Compressor
units in an
extremely dirty and/or hostile environ-
ment will require a greater frequency
of all maintenance checks.
To Check
Safety
Valve
if the safety valve
does not work
properly, over-pressurization
may
occur, causing air tank rupture or
an explosion,
1.
Before star_ing compressor,
pull
the ring on the safety valve to
make sure that the safety valve
operates freely. If the valve is
stuck or does not operate
smoothly, it must be replaced
with the same type of valve.
To Drain Tank
1.
Set the On/Auto/Off
lever to
"OFF".
2.
Pull the regulator knob out and
turn counterclockwise
to set the
outlet pressure to zero.
3.
Remove the air tool or accesso-
ry.
4.
Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psL Release safety valve ring.
5.
Drain water from air tank by
opening drain valve (counter-
clockwise) on bottom of tank.
IIR_'I_
Water will con-
dense in the air
tank. If not drained, water will cor-
rode and weaken the air tank caus-
ing a risk of air tank rupture.
15_ENG
D28071

Advertisement