Nortel NORSTAR Modular ICS 6.1 Manual page 13

Hide thumbs Also See for NORSTAR Modular ICS 6.1:
Table of Contents

Advertisement

Programming overview (Profiles 1 and 4) continued ...
Defaults are shown in bold and underlined
Priv DN len
Type
PrivNetId
Loc code
Priv DN len
Public network
Pub DN lengths
Show prefix:
Prfx:Deflt
DN length
Dial timeout
Dial timeout
Access codes
Line pool codes
Line pool A
Park prefix
Extrnl code
Direct-dial
Auto DN
DISA DN
PrivAccCode
Carrier Codes
Prfx:
ID length:
Prfx:
Remote access
Rem access pkgs
Show pkg:_
00
LinePool access
PRI-A (A-D)
Pool A (9)
Pool B (B-O) ( )
Remote page
01
LinePool access
PRI-A (A-D)
Pool A (9)
Pool B (B-O) ( )
Remote page
Rem line access
Show line:_
L001 Rem pkg
Rec'd # length
DN length
BusName
CbC limits
(NI-2 protocol only)
Pool PRI-A
Service: Public
Min in
Max in
Min out
Max out
Service: Tie
Service: FX
Service: OUTWATS
Service: 800
Pool PRI-B
P0603536 02
Release reasons
3
UDP
Text:
1
None
Hospitality
3
Room/desk info
Show set:___
Room #: _
Adm pwd req'd:
Call restrns
7
Vacant:
Use flt:__
4
Basic:
Mid:
Full:
Service time
Hour:
9
Minutes:
1
Alarm
None
Attn attempts:
Retry intrvl:
0
Attn duration:
None
Time format
Expired Alarms
None
Notify set:
None
Use Tone:
SM sets
10
3
101
Network Services
(SL-1 MCDN only)
MCDN
NetwkICCL
TRO
TAT
N
N
Telco features
N
N
N
VMsg ctr tel#s
N
Y
VMsg center 1
N
Use: Line|routing tbl
N
Tel#:
VMsg center 2
VMsg center 3
00
VMsg center 4
3
VMsg center 5
ONN blocking
3
Analog VSC
None
Tone
Pulse
BRI VSC
Code
Software keys
(Used to activate ISDN PRI and fixed access
trunks/WAN access for Data Modules)
(MICS-XC: also activates Companion
features.)
SysID
(8 digits)
None
Password keys
Key 1
(8 digits)
Key 2
(8 digits)
Key 3
(8 digits)
Y
Hardware
00
Show Module:_
00
00
Cards on KSU
00
Cd1-KSU
Card type
00
Lines
00
Discon timer
(If T1 card)
3
4
Card type
15
Lines
12hr
Discon timer
Answer timer
None
N
CO fail
I/F levels
5
Framing
Internal CSU
CSU line bld
DSX1 bld
Line coding
N
Clock Src
Y
(If PRI card)
Card type:
N
Lines
(If protocol is for MCDN)
Protocol
PrivNetID
Type
BchanSeq
ClockSrc
Max transits
no number
(If more than one Protocol)
Protocol
PrivNetID
BchanSeq
CbC Routing
(If Protocol is DMS-100)
CbC values
FX
800
None
(If Protocol is NI-2)
None
CbC values
FX
None
800
(If Protocol is DMS-250)
CbC values
FX
800
900
(If Protocol is AT&T-4ESS)
CbC values
FX
800
I800
900
SDS
CO fail
I/F levels:
Framing
Internal CSU
CSU line bld
Line coding
Clock Src
(If DID card)
Card type
Lines
(If E&M card)
Loop
Card type
Loop
Lines
Answer timer
460
(If BRI card)
Card type
T1
Loops
Loop aaa
460
Type
2
Protocol
T1A-547A
Sampling
(For S and LT)
ISDN
Assign DNs
ESF
Show DN: _
On
Loop DN:_
0
(For T & NT)
000-100
SPIDn
B8ZS
# of B-channels
Primary
Network DNs
DN1
PRI
Call type
D-packet service
D-packet servc
LPnnn
SL1
TEIs
1
TEI
Slave
Clock Src
Descend
ONN blk
Primary
DataMod settings for Profile 1 only
31
(If DataMod=IDM 200)
Type
Fixed access
NI-2
Show line:_
30
L001:
Descend
L001:
DataMod NVRAM
(If DataMod=BayStack)
Type
None
IP address
None
Fixed access
Show line:_
L001:
L001:
None
Switched access
None
Line assignment
Show line:_
L001:
None
LinePool access
None
LinePool PRI-A:
None
L001:
Dial-in:
(If DataMod=SDI)
None
Type
None
Modular ICS 6.1 Programming Record
5
None
None
None
TIA-547A
ISDN
ESF
On
0
B8ZS
Primary
DID
E&M
2
T
Fixed
Availabl
None
1
Both
None
Primary
SuprsBit
IDM 200
Unassigned
Channel:xx
BayStack
Unassigned
Channel:xx
Unassigned
N
Unassigned
None
(MICS-XC only)
SDI

Advertisement

Table of Contents
loading

Table of Contents