Nortel 1000 Applications Installation And Commissioning page 89

Linux platform base
Table of Contents

Advertisement

Figure 84
Primary Security Service fingerprint window
12
Installing the Element Manager joining an existing secure network
Step
1
2
3
4
5
6
Linux Platform Base and Applications Installation and Commissioning
Copyright © 2007–2008 Nortel Networks
.
The nortel password screen appears. Type the password of the
nortel account and press Enter. The connection to the Primary
Security Service server is complete and the installation finishes.
The installation takes approximately 30 minutes to complete.
After the installation is complete the disk automatically ejects
from the drive and a summary of the installation is shown on the
screen.
For detailed information about Element Manager see Element
Manager System Reference—Administration (NN43001-632) () .
Action
Log on to the server using the nortel account.
Insert the MGMT DVD in the DVD tray.
Enter the appinstall CLI command.
At the prompt, enter the root account password.
The system then prompts you to check the media.
Enter Y to check the media, or N to proceed without checking the
media, and press Enter.
The Application Installation screen appears, as shown in
Figure 85 "Application Installation window" (page
Application installation window select 3 to install the Element
Manager joining an existing secure network. The appropriate
packages are installed to the hard drive.
Nortel Communication Server 1000
NN43001-315 02.09
29 October 2008
Install the CS 1000 applications 89
--End--