Motor Specifications And Electrical Requirements; Connecting To Power Source Outlet; Check Motor Rotation - Craftsman 113.20680 Owner's Manual

6 1/8-inch jointer-planer
Table of Contents

Advertisement

motor specifications and electrical requirements
]'his
machine
is designed
to use a 3450
RPM
motor
only.
Do
not
use any
motor
that
runs
faster
than
3450
RPM.
It is wired
for
operation
on
1t0-120
volts,
60 Hz,,
alter-
nating
current.
IT
MUST
NOT
BE
CONVERTED
TO
OPERATE
ON
230
VOI.TS.
EVEN
THOUGH
SOME
OF
]-HE
RECOMMENDED
MOTORS
ARE
DUAL
VOLTAGE.
THESE
CRAFTSMAN
MOTORS
HAVE
BEEN
FOUND
TO BE ACCEPTABLE
FOR
USE ON
THIS
TOOL.
H P
R P.___M
VOLTS
CATALOG
NO.
1/2
3450
110-120
12t6
t/2
3450
110-120
1218
3/4
3450
1t0-120
1219
3/4
3450
t10-120
1226
CAUTION:
Do not use blower
or washing machine
motors
or any motor
with
an automatic
reset overload
protector
as their
use may be hazardous,
CONNECTING
TO POWER SOURCE
OUTLET
This
machine
must
be grounded
while
in use to protect
the operator
from
electric
shock.
Plug power
cord
into
a 1 t0-120V
properly
grounded
type
outlet
protected
by a 15-amp.
time
delay
or Circuit-Saver
fuse or circuit
breaker.
If you
are not sure that your
outlet
is properly
grounded,
have it checked
by a qualified
electrician,
WARNING:
DO NOT PERMIT
FINGERS
TO TOUCH
THE TERMINALS
OF PLUGS WHEN INSTALLING
OR
REMOVING
THE PLUG TO OR FROM THE OUTLET.
WARNING:
IF NOT
PROPERLY
GROUNDED
THIS
POWER TOOL CAN INCUR THE POTENTIAL
HAZARD
OF ELECTRICAL
SHOCK, PARTICULARLY
WHEN USED
IN DAMP LOCATIONS
IN PROXIMITY
TO PLUMBING.
IF AN ELECTRICAL
SHOCK OCCURS THERE
IS THE
POTENTIAL
OF A SECONDARY
HAZARD
SUCH AS
YOUR
HANDS
CONTACTING
THE CUTTING
BLADE.
!f power
cord
is worn
or cut, or damaged
in any way, have
it replaced
immediately.
PROPERLY
GROUNDED
OUTLET.
3--PRONG
PLUG
GROUNDING
PRONG
This
power
tool
is equipped
with
a 3-conductor
cord
and
grounding
type plug which
has a grounding
prong,
approved
by Underwriters'
Laboratories
and the Canadian
Standards
Association.
The
ground
conductor
has a green jacket
and
is attached
to the tool housing
at one end and to the ground
prong in the attachment
piug at the other end.
This
plug
requires
a mating
3-conductor
grounded
type
outlet
as shown.
If the outlet
you are planning
to use for this power
toot is
of
the
two
prong
type
DO
NOT
REMOVE
OR
ALTER
THE
GROUNDING
PRONG
tN ANY
MANNER.
Use an
adapter
as shown
and always
connect
the grounding
tug to
known
ground.
It
is recommended
that
you
have
a qualified
electrician
replace
the
TWO
prong
outlet
with
a properly
grounded
THREE
prong
outlet.
An
adapter
as shown
below
is available
for connecting
plugs
to 2-prong
receptacles.
The green
grounding
lug
extending
from
the adapter
must
be connected
to a permanent
ground
such as to a properly
grounded
outlet
box,
MAKE
SURE
THIS
IS
CONNECTED
TO A
KNOWN
GROUND
2-PRONG
RECEPTACLE
------'-_
GROUNDING
LUG
ADAPTER
/
3--PRONG
"-""-_.F._,/
PLUG
NOTE:
The adapter
iltustrated
is for use only
if you already
have
a properly
grounded
2-prong
receptacle.
Adapter
is
not
allowed
in
Canada
by the
Canadian
Electrical
Code.
The
use of any
extension
cord
will
cause some
loss
of
power.
To keep
this
to a minimum
and to prevent
over-
heating
and
motor
burn-out,
use the table
below
to deter-
mine
the minimum
wire size (A.W.G.)
extension
cord.
Use
only
3 wire extension
cords which
have 3-prong
grounding
type
plugs
and 3-pole
receptacles
which
accept
the tools
plug.
Extension
Cord
Length
Wire
Size
A.W.G.
Upto
100 Ft.
!4
100-
200 Ft,
12
200-
400 Ft.
8
CHECK
MOTOR
ROTATION
WARNING:
FOR YOUR
OWN SAFETY,
MAKE SURE
PLUG IS NOT CONNECTED
TO POWER SOURCE OUT-
LET WHEN CHANGING
MOTOR ROTATION.
The
motor
must
rotate
COUNTERCLOCKWISE
when
viewed
from
the shaft
end to which
you wit_ mount
the
pulley,
(See page
9),
if
it does
not,
change
the direction
according
to the
instructions
furnished
with
the
motor.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents