Controller module installation guide
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:

Advertisement

If you are unsure which controller is the primary, verify from the front panel. Use the information below to
discover which controller is the primary.
KEY
CANCEL CANCEL
MENU
ENTER
+
3.
Once this is complete, you can use this tape as a boot tape to run ARDIAG on any PA-RISC system
using an AutoRAID product as a boot device. Shutdown HP-UX system and reboot the system from the
tape.
4.
At "Interact with IPL (y or n)?", answer "y".
5.
At ISL>, type "ODE ARDIAG".
6.
Enter the password at this point.
7.
ARDIAG will scan the array busses and report those on the screen (each bus will be referenced by an
index number).
8.
At the "Please enter a range of the disk array busses you want to check," select only the range (by index
number) that the array(s) is on. If you select the default range (index numbers of all busses found), this
process could take 5+ minutes.
9.
After checking the array busses, ARDIAG will search for firmware files on the tape and report those to
you as well. The firmware files located on the tape will present you a table that looks like the
following:
File name
C3586AHPxx
C5447AHPxx
22
DISPLAY
"Ready"
"Language"
"View Settings"
"System State: Ready"
"Primary Cntrl: __"
Intended Product ID
HPC3586A disk array
HPC5447A disk array
Revision
Size
HPxx
1048576
HPxx
2097152

Advertisement

loading

This manual is also suitable for:

Surestore e disk array 12h