10. Verify if the primary controller currently installed has the desired firmware using the front panel
display. The following table shows the proper front panel commands to view which controller is the
primary array controller, and what version of firmware is on the primary array controller.
KEY
CANCEL CANCEL
MENU
–
ENTER
+
+
+
+
+
11. Copy the firmware from the primary controller to the secondary controller using the front panel:
KEY
CANCEL CANCEL
MENU
+
ENTER
–
ENTER
ENTER
12. The front panel display should say "Not Enough Disks". Check the "System State" on the front panel
display. It should say "Not Enough Disks" with no other warnings.
KEY
CANCEL CANCEL
MENU
–
ENTER
+
16
DISPLAY
"Not Enough Disks"
"Language"
"View Settings"
"System State: Not Enough Disks"
"Warning: Firmware Needed"
"Primary Cntrl: X"
"SCSI ID x: ___"
"SCSI ID y: ___"
"Firmware: HP__"
DISPLAY
"Not Enough Disks"
"Language"
"Cntrl Changes"
"SCSI ID"
"Copy Firmware"
"Confirm"
"Copying Firmware",
then "Firmware Loading",
then array will initialize
then "Offline SCSI ID"
DISPLAY
"Not Enough Disks"
"Language"
"View Settings"
"System State: Not Enough Disks"
"Primary Cntrl: X"
Need help?
Do you have a question about the Surestore Disk Array 12h - And FC60 and is the answer not in the manual?
Questions and answers