Receiver Scan Rate - Ericsson LBI-39012A Operator's Manual

Mdx conventional mobile radio
Table of Contents

Advertisement

3.
Press the CHANNEL/SEL (+) button until the desired priority level
is displayed by the scan priority indicators on the right side of the
display; the choices are S, P2; P1 or all off (all off removes the channel
from the SCAN list).
4.
Press the CLR button when completed to return to normal operation.
If your radio has one of the auxiliary keys preprogrammed to edit the SCAN
list, the list may be changed by using the CHANNEL/SEL buttons to display
the CHANNEL name, and then pressing the auxiliary key until the desired
level is displayed.
1.
The radio will remember the scan state through a power cycle
unless programmed with a predefined power up state.
2.
The radio may be programmed to stop scanning when the
microphone is removed from the hookswitch.
3.
When the radio is programmed, a FIXED SCAN list can be
specified. If this is done, the SCAN list cannot be changed.
4.
A previous channel with priority will become a non-priority scan
channel when a new priority channel is programmed.
The SCAN function allows monitoring of up to 1 6 receive channels on the
selected system. The scanned channels may be any frequency within the
frequency band limits of the radio and may be Channel Guard protected. All
scan functions are retained in memory, even if the 12 Volt vehicle battery is
disconnected.
Any channel may be scanned with or without a priority level. One channel
may be programmed for Priority 1 (P1) and another for Priority 2 (P2) with
any or all remaining channels programmed as non-priorities.

RECEIVER SCAN RATE

The scan rate for the radio will vary depending upon the number of channels
programmed into the scan list and whether or not Channel Guard is
programmed. The scan rate will be faster when fewer channels are program-
med into scan memory.
NOTES