Configuring switched point-to-point FICON
22
TABLE 2
FICON switch parameters (Continued)
Parameter
Sequence level switching
Disable device probing
Suppress Class F traffic
Per-frame route priority
Long-distance fabric
Insistent Domain ID mode
Virtual Channel parameters
F-Port login parameters
Maximum logins per switch
Maximum logins per port
Maximum logins per second
Login stage interval
Zoning operation parameters
Response
Comment
0
Do not change. When set to 1, frames of the same
sequence from a particular source are transmitted
together as a group. When set to 0, frames are
interleaved among multiple sequences when
transmitted. Under normal conditions, sequence-level
switching should be disabled for better performance.
1
The recommended best practice is to disable device
probing. When disable device probing is set to 1,
devices that do not register with the Name Server will
not be present in the Name Server database.
0
Do not change. By default, the switch can send Class F
frames. When this option is turned on (set to 1),
Class F traffic is converted to Class 2 traffic before
being transmitted to support remote fabrics that
involve ATM gateways.
0
Do not change. In addition to the virtual channels used
in frame routing priority, when this value is set to 1,
support is also available for per-frame-based
prioritization.
0
Do not change. The recommended best practice is to
configure individual ports for long distance when
cascading at extended distances.
Yes
The recommended best practice is to set the domain
ID to be insistent. Setting the insistent domain ID is
required for 2-byte addressing.
No
Do not change. The switch allows fine-tuning of a
specific application through virtual channels
parameters. The default virtual channel settings have
already been optimized for switch performance.
Changing these values can improve switch
performance, but can also degrade performance.
No
With Fabric OSv6.1.0 and later, it is not necessary to
make any changes to F_Port login parameters. The
only other reason to answer yes (y) to this prompt is if
NPIV is being used and there is a need to change the
default number of NPIV logins.
Change this only if NPIV is being used and the number
of fabric logins will exceed the default or there is a
need to limit the number of logins.
Change this only if NPIV is being used and the number
of port logins will exceed the default or there is a need
to limit the number of logins.
For Fabric OS v6.1.0b and later – Do not change. Leave
at default.
NOTE: The default value is incorrectly shown as 0.
Do not change. Specifies the stage interval in the
staged F_Port login, in milliseconds.
No
Do not change. Disables and enables NodeName Zone
Checking.
FICON Administrator's Guide
53-1002753-01