Telnet Commands
The telnet commands for Advanced Performance Monitoring become available
through the shell "admin" account when the Advanced Performance Monitoring
license key is installed. To use a telnet command, log into the relevant switch with
administrative privileges, enter the command along with any required arguments,
and press Enter.
Using telnet commands, you can track the following:
For a description of all the telnet commands provided for performance
monitoring, refer to the HP StorageWorks Fabric OS Version 3.1.x/4.1.x
Reference Guide.
Using AL_PA Error Performance Monitoring
AL_PA error performance monitoring tracks and displays the number of CRC
errors that have occurred on frames sent to each AL_PA on a specific port.
AL_PA-based error performance monitoring does not require an explicit
configuration. The switch hardware and firmware automatically monitor CRC
errors for all valid AL_PAs.
Displaying the CRC Error Count
Use the perfShowAlpaCrc command to display the CRC error count for all
AL_PA devices for a single AL_PA on a specific port. The port must be an active
L_Port.
Example 1. This command displays the CRC error count for all AL_PA devices
on port 3:
Advanced Performance Monitoring Version 3.1.x/4.1.x User Guide
Number of CRC errors for AL_PA devices
Number of words received and transmitted in Fibre Channel frames with a
defined SID/DID pair
Number of frames with CRC errors with a defined SID/DID pair
Number of times a particular filter pattern in a frame is received by a port
sw1:admin> perfShowAlpaCrc 3
AL_PA
CRC count
--------------------
0x01
2
0x02
0
0x04
1
Using Advanced Performance Monitoring
37