Download Print this page

Frigidaire FPEF4085KF Product Specifications page 3

40" electric freestanding range
Hide thumbs Also See for FPEF4085KF:

Advertisement

Professional
Freestanding Range Specifications
Product Shipping Weight (approx.) – 235 Lbs.
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt,
60 Hertz, fused on both sides of line with ground. (If local code
permits, range may be connected by hard-wiring or by means
of power supply cord kit.)
Connected Load (kW Rating) @ 240 / 208 Volts = 12.8 / 9.6 kW
Amps @ 240 / 208 Volts = 53.0 / 46.0 Amps
Recommended Circuit Breaker – 50 Amps (40 Amps minimum)
Always consult local and national electric codes.
Make sure wall coverings around range can withstand heat generated
by range.
Linoleum or any other synthetic floor covering located beneath range,
must be capable of withstanding minimum heat of 90° F above room
temperature without shrinking, warping or discoloring. Insulating pad
or 1/4"-thick plywood required between range and a carpeted floor.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
USA
10200 David Taylor Drive
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
FPEF4085K 10/10
Charlotte, NC 28262
1-800-FRIGIDAIRE
1-800-265-8352
© 2010 Electrolux Home Products, Inc.
Allow 24" minimum clearance between rangetop and bottom of cabinet
when bottom of wood or metal cabinet is protected by not less than
1/4" flame-retardant millboard covered with not less than No. 28 MGS
sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper.
Allow 30" minimum clearance when cabinet is unprotected.
To reduce risk of fire when using overhead cabinetry, install
range hood that projects horizontally a recommended minimum
of 5" beyond bottom of cabinets.
0" clearance required (minimum 2" recommended) from edge
of rangetop to nearest combustible wall on either side of range
above 36" height.
Range can be installed flush to wall with 0" minimum rear clearance.
For installation against left side wall that extends to or beyond
range's side panel, allow 2-3/4" minimum clearance to allow
auxiliary oven door to open.
Follow all dimension requirements provided to prevent property
damage, potential fire hazard, and incorrect countertop and
cabinet cuts.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
frigidaire.com
frigidaire.ca
Freestanding Range
FPEF4085K F
40" Electric
Specifications
subject to change.
Printed in the U.S.A.

Advertisement

loading