Operating Status: Application Server Volume Properties; Storage Tab: Application Server Volume Properties - HP StorageWorks All-in-One SB600c - Storage Blade User Manual

Hp storageworks all-in-one storage manager user guide (452695-003, june 2008)
Hide thumbs Also See for StorageWorks All-in-One SB600c - Storage Blade:
Table of Contents

Advertisement

2.
Do one of the following:
• Select an application server volume in the content pane and then click Properties in the Actions
pane.
• Right-click an application server volume in the content pane and select Properties.
3.
Click one of the following tabs:
• General tab—Displays the name of the volume on the application server, the volume type,
and status:
Table 29 Operating status: Application server volume properties
Status indicator
OK
Warning
Critical
• Storage tab—Displays the unallocated space, used space, free space on the volume, and the
following storage allocation details:
Table 30 Storage tab: Application server volume properties
Property
Application Server Host Name
Application Server Volume -
Name
Application Server Volume -
Status
Application Server Volume -
Exclusive Storage
Application Server Volume -
RAID Level
Application Server Volume -
RAID Stripe Size
Application Server Volume -
Read Cache
Application Server Volume -
Write Cache
Application Server Volume -
Number of Hot Spares
Application Server Volume -
Mount Paths
62
Monitoring storage
Value
The storage is online.
See the Alerts list for more information. See
for alert descriptions.
See the Alerts list for more information. See
for alert descriptions.
Value
Name of the application server where the volume resides.
Name of the volume on the application server. Volume is located
on the iSCSI LUN exported by ASM.
Status of the volume on the application server.
Indicates if the volume on the application server is configured with
exclusive storage. See
Table 4
The RAID level to which the volume on the application server is
configured. See
Customizing RAID levels
information.
The RAID stripe size to which the volume on the application server
is configured. See
Table 4
Speeds up reads when enabled. This setting is determined by the
storage array, not ASM.
Speeds up writes when enabled. This setting is determined by the
storage array, not ASM.
The number of hot spares with which the volume on the application
server is configured. See
Table 4
Path the volume is mounted on.
Table 32
Table 32
on page 21 for more information.
on page 23 for more
on page 21 for more information.
on page 21 for more information.
on page 67
on page 67

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks all-in-one storage manager

Table of Contents