Error codes

Table 4 Error codes
Error code
Cn01
Fn00 – Fn67
Hn00 – Hn29
Hn30
Hn31–66
Hn67

Fan module LEDs

Item
Description
1
Fan module LED
24
LED descriptions
Description
Configuration error—Hardware not
supported
Firmware error
Hardware error—Controller error
Hardware error—Fatal ECC error
Hardware error—Controller error
Hardware error—SAS expander error
Status
Green—Normal operation
Blinking amber—Fan fault condition exists
Off—Fan unseated from connector or has failed
Required action
Log error, check hardware and cable
connections.
Log error, restart enclosure. If error persists,
contact HP support.
Log error, contact HP support, replace
controller.
Log error, contact HP support, replace
cache module.
Log error, contact HP support, replace
controller.
Log error, contact HP support, verify
cabling. If error persists, replace controller.