Remove the power button/UID board.
9.
To replace the component, reverse the removal procedure.
Cable management arm
To remove the component:
Power down the MDS600
1.
Disconnect all cables.
2.
Remove all power supplies
3.
Remove the fans ("Fan" on page 29).
4.
Remove all hard drives
5.
Be sure the hard drive drawer is closed all the way.
6.
Remove the I/O modules
7.
Remove the power block
8.
Remove the hard drive drawer
9.
Remove the T-15 Torx screw that secures the cables to the hard drive drawer, and then remove the
10.
cables.
("Power
down" on page 24).
("Power
supply" on page 30).
("Hard
drive" on page 26).
("Hot-plug I/O
module" on page 30).
("Power
block" on page 35).
("Hard drive
drawer" on page 31).
Removal and replacement procedures 41
Need help?
Do you have a question about the StorageWorks 9100 - Extreme Data Storage System and is the answer not in the manual?
Questions and answers