Summary of Contents for Altinex Video and S-Video Distribution Amplifier Cards MT103-118
Page 1
MULTI-TASKER MT103-120 is pictured above. MANUAL PART NUMBER: 400-0185-002 MT103-118/120 DUAL 1-IN, 3-OUT VIDEO and S-VIDEO DISTRIBUTION AMPLIFIER CARDS FOR MULTI-TASKER™ ENCLOSURES USER’S GUIDE...
MT103-118/120 and to prevent fire and shock hazard. Please read them carefully and heed all warnings. 1.1 GENERAL Qualified ALTINEX service personnel, or their authorized representatives must perform all service. 1.2 INSTALLATION To prevent fire or shock, do not expose this unit to rain or moisture.
ABOUT YOUR MT103-118/120 MT103-118/MT103-120 Dual 1-in 3-out Video & S-Video Distribution Amplifier Card The MT103-118/120 is a dual 1-in 3-out Composite (C) Video and S-Video Distribution Amplifier (DA) Card. There is one BNC C-Video input with three BNC C-Video outputs and one S-Video input with 3 S-Video outputs.
Page 6
Application Diagram 2: Internal View of MT103-118/120 S-VIDEO 4 PIN MINI-DIN INPUT 1 VIDEO INPUT 1 S-VIDEO 4 PIN MINI-DIN INPUT 1 VIDEO INPUT 1 MT103-120 POWER OUTPUT ON/OFF CONTROL MT103-118 POWER MULTI-TASKER S-VIDEO 4 PIN MINI-DIN OUT 1 OUT 2 OUT 3 VIDEO OUT 1...
INSTALLING YOUR MT103-118/120 Step 1. Slide MT103-118/120 available slot Enclosure in order to connect to the bus. Make sure that the MT103-118/120 card fits into place. Secure the card to the Multi-Tasker™ by tightening the retainer screws located on the top and bottom of the MT103-118/120 card.
Page 8
Command Format: [VERCnUi] Cn = card ID (n = slot # from 1 to 19) (1-8 for MT100-101 or 1-4 for MT100-106) Ui = Unit ID (i = # from 0 to 9) (refer to the MT100-100 user’s guide for explanation) Example: If one MT103-120 card is in slot #2 of unit 3: When sending command...
Page 9
9. […F] – Feedback After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string or if the unit ID is zero. 10. […P] – Path This command will set the path for the output, but it is not active until the switch command, [SW], is executed.
LED lights, the problem is the card cage slot. The card cage may require service. Call ALTINEX at (714) 990-2300. If the other slots do not work and the LED is still not lit, see Solution 2.
Solution 2. Solution 2: Turn the system OFF and then ON again. If there is still an error, see Solution 3. Solution 3: Call ALTINEX at (714) 990-2300. 8.3 NO DISPLAY Cause 1: The source has a problem.