Customer Responsibilities; To Check Safety Valve; To Drain Tank - Craftsman 919.152120 Operator's Manual

Permanently lubricated tank mounted air compressor
Table of Contents

Advertisement

Customer
Responsibilities
Check Safety Valve
Drain Tank
Before each use
e
Daily or after
each use
2.
Pull the regulator knob out and turn clockwise to
set the outlet pressure to zero.
3.
Remove the air tool or accessory.
4.
Pull ring on safety valve allowing air to bleed from
the tank until tank pressure is approximately
20
psi. Release safety valve ring.
5.
Drain water from air tank by opening drain valve
(counter-clockwise)
on bottom of tank.
To Check
Safety Valve
If the safety valve does
not work properly, over-
pressurization
may occur, causing air tank
rupture or an explosion.
Before starting com-
pressor, pull the ring on the safety valve to
make sure that the safety valve operates
freely. If the valve is stuck or does not operate
smoothly, it must be replaced with the same
type of valve.
To Drain
Tank
1.
Set the On/Auto/Oft lever to "OFF".
6,
Valve
Water will condense in
the air tank. If not
drained, water will corrode and weaken the air
tank causing a risk of air tank rupture.
After the water has been drained, close the drain
valve (clockwise).
The air compressor
can now
be stored.
NOTE: If drain valve is plugged, release all air pres-
sure. The valve can then be removed, cleaned, then
reinstalled.