Maintenance; Customer Responsibilities - Craftsman 919.152160 Owner's Manual

Permanently lubricated tank mounted air compressor
Hide thumbs Also See for 919.152160:
Table of Contents

Advertisement

Available languages

Available languages

Customer Responsibilities

Check Safety Valve
Drain Tank
Remove tank from service
- For more information, Contact a Trained Service Technician.
1
power is on. When performing
maintenance, you may be exposed
to voltage sources, compressed air,
or moving parts. Personal injuries
can occur. Before performing any
maintenance or repair, disconnect
power source from the compressor
and bleed off all air pressure.
NOTE: See Operation section for the
location of controls.
To Check Safety Valve
does not work properly, over-
pressurization may occur, causing
air tank rupture or an explosion.
wear certified safety equipment:
ANSI Z87.1 eye protection (CAN/CSA
Z94.3) with side shields
Before starting compressor, pull the ring
on the safety valve to make sure that the
safety valve operates freely. If the valve
is stuck or does not operate smoothly,
it must be replaced with the same type
of valve.
To Drain Tank
from noise. Air tanks contain high
pressure air. Keep face and other
body parts away from outlet of
drain. Use ANSI Z87.1 eye protection
(CAN/CSA Z94.3) when draining as
debris can be kicked up into face.

MAiNTeNANCe

Unit cycles
automatically when
Risk of Bursting.
If the safety valve
Risk from Flying
Objects. Always
Risk of Unsafe
Operation. Risk
Before
each use
x
[(ANSI S12.6 (S3.19)] hearing
protection) as air flow noise is loud
when draining.
1.
Set the On/Off switch to "Off".
2.
Turn the regulator knob counter-
clockwise to set the outlet
pressure to zero.
3.
Remove the air tool or accessory.
4.
Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
5.
Drain water from air tank by
opening drain valve on bottom of
tank.
in the air tank. If not drained, water
will corrode and weaken the air tank
causing a risk of air tank rupture.
from air tank may contain oil and
rust which can cause stains.
6.
After the water has been drained,
close the drain valve. The air
compressor can now be stored.
NOTE: If drain valve is plugged,
release all air pressure. The valve
can then be removed, cleaned, the
reinstalled.
14 - ENG
Daily
see tank
or after
warning
each
label
use
x
x(1)
Risk from noise.
Use ear protection
Risk of Bursting.
Water will condense
Risk of Property
Damage. Drain water

Advertisement

Chapters

Table of Contents
loading

Table of Contents