Removing/Replacing The Battery Board (65X Series) - Texas Instruments Extensa 60x Series Maintenance Manual

Table of Contents

Advertisement

6.5.13 Removing/Replacing the Battery Board (65x Series)

1.
Remove the Top Cover Assembly as described in Paragraph 6.5.10.
2.
Disconnect the Battery Board Cable from the Main Board (refer to
Figure 6-17).
3.
Remove the two screws holding the Battery Board and remove the Battery
Board Assembly.
4.
Replacement is the reverse of Steps 1 through 3.
6.5.14 Removing/Replacing Inside Frame Assy. (60x Series)
Use the following procedure to separate the inside frame assembly from the base
assembly:
1.
Remove the Top Cover and Fan Assemblies as described in Paragraphs 6.5.10
and 6.5.11 respectively.
2.
Separate the inside frame assembly from the base assembly as shown in
Figure 6-18.
3.
Replacement is the reverse of Steps 1 and 2.
Figure 6-18 Detaching Base Assembly from Inside Frame Assembly
6.5.15 Removing/Replacing Inside Frame Assy (65x Series)
Use the following procedure to separate the inside frame assembly from the base
assembly on a 65x Series Notebook Computer:
1.
Remove the Top Cover and Fan Assemblies as described in Paragraphs 6.5.10
and 6.5.11 respectively.
Field Service
6-21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents