How To Stop; Before Starting Break-In Procedure; Before Each Start-Up; How To Start - Craftsman 919.167790 Operator's Manual

Permanently lubricated tank mounted
Table of Contents

Advertisement

Available languages

Available languages

How to Use Your Unit
How to Stop:
1.
Set the On/Auto/Off
lever to "OFF".
Before
Starting
Break-in
Procedure
_
Serious damage may result if the
following break-in instructions
are
not closely followed.
This procedure is required before the air compressor
is put into service and when the check valve or a
complete compressor
pump has been replaced.
1.
Make sure the On/Auto/Off
lever is in the "OFF"
position.
NOTE: If quick connect is installed, pull coupler back
until it clicks to prevent air from escaping through the
quick connect.
.
.
Plug the power cord into the correct branch circuit
receptacle. (Refer to Voltage and Circuit
Protection paragraph in the Installation section of
this manual.)
Open the drain valve
fully (counter-clock-
wise) to permit air to
escape and prevent air
Valve
pressure build up in
the air tank during the
break-in period.
4.
Move the On/Auto/Off
lever to "ON/AUTO"
posi-
tion. The compressor
will start.
5.
Run the compressor
for 15 minutes. Make sure
the drain valve is open and there is minimal air
pressure build-up in tank.
6.
After 15 minutes, close the drain valve (clock-
wise). The air receiver will fill to "cut-out"
pressure
and the motor will stop.
The compressor
is now ready for use.
Before
Each Start=Up:
1.
Place On/Auto/Off
lever to "OFF".
.
.
Pull regulator knob out, turn counter-clockwise
until it stops. Push knob in to lock in place.
Attach hose and accessories. NOTE: The hose or
accessory will require a quick connect plug if the
air outlet is equipped with a quick connect.
Too much air pressure
causes a hazardous risk of
bursting. Check the manufacturer's
maximum
pressure rating for air tools and accessories.
The regulator outlet pressure must never
exceed the maximum pressure rating.
How to Start:
1.
Turn the On/Auto/Off
lever to "AUTO" and allow
tank pressure to build. Motor will stop when tank
pressure reaches "cut-out"
pressure.
2.
Pull the regulator knob out and turn clockwise to
increase pressure. When the desired pressure is
reached push knob in to lock in place. The com-
pressor is ready for use.
NOTE: Always operate the air compressor
in well-
ventilated areas free of gasoline or other combustible
vapors. If the compressor
is being used to operate a
sprayer DO NOT place near the spray area.
11 - ENG
D24305

Advertisement