MAINTENANCE
INSTRUCTIONS
For proper and sate operation
keep furnace and furnace area clean.
At regular intervals
turn control valve to otL let
cool and clean inside control and heat exchanger
compartment.
To clean front panel
use only a damp cloth, do not
use any kind of solvent or cleaning
fluid that could leave a residue to burn or give offfumes
when furnace is turned
on.
Remove the blower filter from back of heater and clean as needed.
Filter can be cleaned with garden hose, in bathtub,
sink, etc. Use only water or air to clean.
DO NOT USE ANY CLEANING
SOLUTION
AS THEY COULD
BE
FLAMMABLE
AND COULD CAUSE ODORS.
Dry thoroughly
and re-install.
Do not operate heater without filter
in place.
Have the furnace checked, cleaned, and repaired
by a qualified
service person.
Check venting system,
and burner
operation
prior to use each year.
Follow a regular service and maintenance
schedule
for sate and efficient operation.
Do not obstruct combustion
and ventilation
air. Examine
the venting
system as a routine part of the safety perfor-
mance check on an annual basis.
If the heat exchanger
is removed, check the heat exchanger
intake gasket and draft inducer gasket and replace if there
is any sign of damage.
Be sure all gaskets are in place when the heat exchanger
is replaced.
Failure to replace any gasket that has been damaged
may result in property
damage, personal
injury or loss of life.
Oil the bearings
of the t:an motor every 6 months with S.A.E. 20 oil.
SERVICE
RECORD
Page 16