SYMPTOM
Burner
won't
tuna on
(STANDING
PILOT)
Pilot won't
light, or
stay lit
(Ll.D.
PILOT)
Pilot won't
light
TROUBLE
SHOOTING
CHART
- Continued
POSSIBLE
CAUSES
1. Gas valve not turned
on.
2. No voltage
to valve.
3. Defective
thermostat.
4. No 115 W. Line voltage.
5. Gas valve defective.
6. Manual
reset switch
not engaged.
i. Air in line.
2. Defective
thermoeouple
3. Pilot flame too low.
4. Manual
reset switch
not engaged.
i. Sparker
won't
work.
2. Sparker
won't
light pilot.
3. Manual
reset switch
not engaged.
CORRECTIVE
ACTION
i. Turn gas valve
to "on" position.
2. Check
for 24 Volts to valve from transformer.
3. Check
wall thermostat.
4. Provide
line voltage.
5. Replace
gas valve.
6. Depress
red button
on switch.
1. Bleed
line.
2. Replace
thermocouple.
3. Adjust
pilot flame.
4. Depress
red button
on switch.
1. Check
wire connections,
provide
adequate
ground.
2. {a} Pilot flame too small.
{b} Turn valve to "on" position.
{c} Check for pilot restriction.
3. Depress
red button
on switch.
SERVICE