Fujitsu MB9B100A Series User Manual page 21

32-bit microcontroller fm3 family inverter solution gui user manual
Hide thumbs Also See for MB9B100A Series:
Table of Contents

Advertisement

Name of area
1
Form name
2
Show wave
3
Waveform name
4
Select signal
5
Wave setting
6
Other function
7
System current state
- Notice:
- This window can select compressor contents. System and Fun contents cannot be
selected.
- Wave save and load function are not prepared.
- How to operate Signal selection window
Please refer the chapter "Example of total operating Procedure", too
You can select the data to show the waveform.
The selected parameters are defined wave A through wave D in order.
After selecting, the waveforms are shown the window. As a default, each reference lines
are defined as follows;
Table 5-4: wave observer function
Description
Custom the name of this wave window.
Draw the wave of signal needing to show.
Shown the waveform name, it's come from select signal
Select the signal to show the wave If the button is clicked, the signal
selection window opens.
Select waveform; set waveform color; set the X-grid, Y-grid;
waveform up, down, left, right move; and all setting reset.
Pause/run and save/load wave data.
Show the current state: connect, PFC, compressor, Fan
20
AN706-00044-1v0-E
(See Chapter4.4.3)