Download Print this page

Craftsman 919.168700 Owner's Manual page 14

Permanently lubricated single stage portable air compressor
Hide thumbs Also See for 919.168700:

Advertisement

Available languages

Available languages

4.
Move the On/Auto/Off
lever to
"ON/AUTO"
position. The
compressor will start.
5.
Run the compressor
for 15
minutes. Make sure the drain
valve is open and there is
minimal air pressure build-up in
tank.
6.
After 15 minutes, close the drain
valve (clockwise). The air receiver
will fill to "cut-out"
pressure and
the motor will stop.
The compressor is now ready for use.
Before
Each
Start-Up:
1.
Place On/Auto/Off
lever to
"OFF".
2.
Pull regulator knob out, turn
counterclockwise
until it stops.
Push knob in to lock in place.
3.
Attach hose and accessories.
NOTE: The hose or accessory
will require a quick connect plug
if the air outlet is equipped with a
quick connect.
Risk of Bursting.
Too much air
pressure causes a hazardous
risk
of bursting.
Check the
manufacturer's
maximum pressure
rating for air tools and accessories.
The regulator
outlet
pressure must
never exceed the maximum
pressure
rating.
How to Start:
1.
Turn the On/Auto/Off
lever to
"AUTO" and allow tank pressure
to build. Motor will stop when
tank pressure reaches "cut-out"
pressure.
2.
Pull the regulator knob out and
turn clockwise to increase
pressure. When the desired
pressure is reached push knob in
to lock in place. The compressor
is ready for use.
NOTE: Always operate the air
compressor
in well-ventilated
areas
free of gasoline or other combustible
vapors. If the compressor
is being
used to operate a sprayer DO NOT
place near the spray area.
A05563
14-ENG

Advertisement

loading