Craftsman 919.166701 Owner's Manual

Permanently lubricated 2-stage twin v portable
Hide thumbs Also See for 919.166701:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Owner's Manual
Permanently Lubricated
2-Stage
Twin V
Portable

AIR COMPRESSOR

Model No.
919.166701
• Safety Guidelines
• Assembly
• Operation
• Maintenance
• Service and Adjustments
• Troubleshooting
• Repair Parts
CAUTION:
Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
Visit our Craftsman website: www.sears.com/craftsman
A13570
Rev. 2 08/10/06

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Craftsman 919.166701

  • Page 1: Air Compressor

    • Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman A13570 Rev. 2 08/10/06...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS WARRANTY..........2 SPECIFICATION CHART .
  • Page 3: Specification Chart

    SPECIFICATION CHART Model No. 919-166701 Running Horsepower Bore 2.375” Stroke High Pressure - .54” Low Pressure - 1.45" Voltage-Single Phase 115/60/1 Minimum Branch Circuit Re quire ment 15 amps Fuse Type Time Delay Air Tank Capacity - Gallons Approximate Cut-in Pressure Approximate Cut-out Pressure SCFM @ 40 psig SCFM @ 90 psig...
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire What Could Happen How To Prevent It Always operate the compressor in a...
  • Page 5 HAZARD WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen How To Prevent It Drain tank daily or after each use.
  • Page 6 HAZARD WARNING: Risk of Electrical Shock What Could Happen How To Prevent It Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, If it is not used Never operate compressor with properly it may cause electric shock.
  • Page 7 HAZARD WARNING: Risk of Burns What Could Happen How To Prevent It Never touch any exposed metal parts Touching exposed metal such as the on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns.
  • Page 8 HAZARD WARNING: Risk of Serious Injury or Property Damage When Transporting Compressor (Fire, Inhalation, Damage to Vehicle Surfaces) What Could Happen How To Prevent It Oil can leak or spill and could result Always place COMPRESSOR on a in fire or breathing hazard; serious protective mat when transporting to injury or death can result.
  • Page 9: Glossary

    GLOSSARY When the tank pressure drops to a Become familiar with these terms certain low level the motor will restart before operating the unit. automatically. The low pressure CFM: Cubic feet per minute. at which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
  • Page 10: Assembly

    ASSEMBLY Thread nut (A) onto shoulder Contents of Carton bolt and tighten firmly with a 1 - Air Compressor 9/16" wrench. Repeat to install 2 - Wheels second wheel. 2 - Shoulder Bolts, 3/8-16 2 - Hex Nuts, 3/8-16 2 - Rubber Bumpers 2 - Screws, 1/4-20 x .75"...
  • Page 11: Installation

    INSTALLATION HOW TO SET UP YOUR IMPORTANT: The outlet being used must be installed and grounded in UNIT accordance with all local codes and ordinances. Location of the Air Compressor Make sure the outlet being used Locate the air compressor in a has the same configuration clean, dry and well ventilated area.
  • Page 12 Extension Cords Voltage and Circuit Protection Using extension cords is not Refer to the Parts Manual for the recommended. The use of extension voltage and minimum branch circuit cords will cause voltage to drop requirements. resulting in power loss to the motor Certain air compressors can be and overheating.
  • Page 13: Operation

    OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Drain Valve (not shown): The Pressure Release Valve (not drain valve is located at the base shown): The pressure release valve...
  • Page 14 Outlet Pressure Gauge (D): The To operate "Quadraport" outlet pressure gauge indicates the attached: air pressure available at the outlet Attach 3/8" hoses (A) with 1/4" side of the regulator. This pressure industrial quick-connect fittings is controlled by the regulator and is (B) to the outlets (C).
  • Page 15 Hold "quadraport" and pull Attach 3/8" hoses (A) with 1/4" quick- connect coupler (D) back industrial quick-connect plugs (B) to release and remove as shown. to the outlets (C). One to four tools can be used at the same time. Attach one end of a 1/2"...
  • Page 16: How To Use Your Unit

    7. Move the On/Auto/Off lever How to Use Your Unit to "ON/AUTO" position. The How to Stop: air receiver will fill to "cut-out" pressure and the motor will Set the On/Auto/Off lever to stop. "OFF". The compressor is now ready for Before Starting use.
  • Page 17: Maintenance

    MAINTENANCE Customer Responsibilities Daily Before Every Every or after each Yearly each hours hours Check Safety Valve Drain Tank Air Filter Air compressor pump intake and exhaust valves 1- more frequent in dusty or humid conditions Unit cycles To Check Safety Valve automatically when If the safety valve power is on.
  • Page 18 After the water has been drained, Air Compressor Pump Intake close the drain valve (clockwise). and Exhaust Valves The air compressor can now be Once a year have a Trained Service stored. Technician check the air compressor NOTE: If drain valve is plugged, pump intake and exhaust valves.
  • Page 19: Service And Adjustments

    SERVICE AND ADJUSTMENTS Unit cycles automatically Outlet Tube when power is on. When doing Pressure Maintenance, you may be exposed Relief Check to voltage sources, compressed air Tube Valve or moving parts. Personal injuries can occur. Before performing any Maintenance or repair, unplug the compressor and bleed off all air pressure.
  • Page 20: Storage

    STORAGE Before you store the air compressor, 10. Store the air compressor in a make sure you do the following: clean and dry location. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary. Set the "ON/AUTO" lever to "OFF".
  • Page 21: Troubleshooting Guide

    TROUBLESHOOTING Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM CAUSE CORRECTION...
  • Page 22 PROBLEM CAUSE CORRECTION Pressure reading It is normal for "some" If there is an excessive on the regulated pressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the used.
  • Page 23 PROBLEM CAUSE CORRECTION Regulator will Damaged regulator. Replace. not shut off air outlet. Motor will not Motor overload protection Let motor cool off and run. overload switch will switch has tripped. automatically reset. Tank pressure exceeds Motor will start automatically when tank pressure drops pressure switch "cut-in"...
  • Page 24: Repair Parts

    AIR COMPRESSOR DIAGRAM Air Compressor Model Number 919.166701 24- ENG A13570...
  • Page 25: Parts List

    PARTS LIST Air Compressor Model Number 919.166701 25 - ENG A13570...
  • Page 26 PUMP DIAGRAM Air Compressor Model Number 919.166701 26- ENG A13570...
  • Page 27 PARTS LIST Air Compressor Model Number 919.166701 27 - ENG A13570...
  • Page 28: Español

    CONTENIDO GARANTÍA............28 CUADRO DE ESPECIFICACIONES .
  • Page 29: Cuadro De Especificaciones

    CUADRO DE ESPECIFICACIONES Modelo Nº 919-166701 Potencia de trabajo Orificio 2.375" Carrera Presión de alto - .54" Presión de mugir - 1.45" Voltaje - Una Fase 115/60/1 Requerimientos Mínimos de Circuito 15 Amperios Tipo de Fusible Retardo Capacidad del Tanque de Aire - Galon Presión de Arranque Aproximada Presión de Corte Aproximada SCFM @ 40 psig...
  • Page 30 INSTRUCCIONES IMPORTANTES DE SEGURIDAD GUARDE ESTAS INSTRUCCIONES La operación o el mantenimiento inadecuados de este producto podrían ocasionar serias lesiones y daños a la propiedad. Lea y comprenda todas las advertencias e instrucciones de funcionamiento antes de utilizar este equipo. PELIGRO ADVERTENCIA: Riesgo de Explosión o Incendio qué...
  • Page 31 PELIGRO ADVERTENCIA: Riesgo de Explosión Tanque de aire: las siguientes condiciones podrían, causar el debilitamiento del tanque, y determinar su explosión violenta, daños a la propiedad o serias lesiones. qué puede occurrir cómo prevenirlo Drene el tanque diariamente o después de Drenaje inadecuado del agua condensada cada uso.
  • Page 32 PELIGRO ADVERTENCIA: Riesgo de Descarga Eléctrica qué puede occurrir cómo prevenirlo Jamás opere el compresor a la intemperie Su compresor de aire está accionado por cuando está lloviendo o en condiciones de electricidad. Como cualquier otro dispositivo eléctrico impulsado eléctricamente, si no se lo humedad.
  • Page 33 PELIGRO ADVERTENCIA: Riesgo de Quemaduras qué puede occurrir cómo prevenirlo Jamás toque partes de metal expuestas en el Tocar el metal expuesto tal como el compresor durante o inmediatamente después cabezal del compresor o los tubos de salida de la operación. el compresor permanecerá del escape, puede ocasionarle serias caliente por varios minutos luego de la quemaduras.
  • Page 34 PELIGRO ADVERTENCIA: Riesgo de Serias Lesiones o Daños a la Propiedad al Transportar el Compresor (Fuego, inhalación, daño a la superficie de vehículos) qué puede occurrir cómo prevenirlo Deposite el compresor sobre una alfombrilla El aceite puede derramarse y ello podría protectora cuando lo transporte.
  • Page 35: Glosario

    GLOSARIO Presión mínima de corte: Cuando el Familiarícese con los siguientes términos, motor está apagado, la presión del tanque antes de operar la unidad: de aire baja a medida que usted continúa CFM: (Cubic feet per minute) Pies cúbicos usando su accesorio. Cuando la presión por minuto.
  • Page 36: Ensamblado

    ENSAMBLADO Enrosque la tuerca (A) en el perno de Contenido de la Caja tope y ajústela firmemente con una 1 - Compresor de aire llave 9/16 pulg. Repita la operación para instalar la segunda rueda. 1 - Bolsa de piezas conteniendo lo siguiente: 1 - Manual del operador 1 - Manual de piezas...
  • Page 37: Instalación

    INSTALACIÓN Asegúrese de que el tomacorriente CÓMO PREPARAR LA UNIDAD que será utilizado tenga la misma configuración que el enchufe de Ubicación del compresor de aire conexión a tierra. Ubique al compresor de aire en una NO UTILICE UN ADAPTADOR. Ver zona limpia, seca y bien ventilada.
  • Page 38 Cables de extensión eléctrica Protección del voltaje y del circuito No se recomienda la utilización de cables Acerca del voltaje y la mínima cantidad de de extensión eléctrica. El uso de cables circuitos requeridos, refiérase al Manual de extensión eléctrica originará una de piezas.
  • Page 39: Operación

    OPERACIÓN Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicación de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
  • Page 40 Válvula de Seguridad (C): Si el Panel portátil de control interruptor de presión no apaga el "Quadraport" compresor de aire en la presión de Conecte mangueras de 3/8 pulg. corte prefijada, la válvula de seguridad (A) con acoplamientos rápidos (B) protegerá...
  • Page 41 Sostenga el "Quadraport" y tire del Conecte las mangueras de 3/8 acoplamiento rápido (D) hacia atrás pulg. (A) con el acoplamiento rápido con el objeto de liberar y soltar de de tipo industrial (B) a las salidas acuerdo a lo mostrado. (C).
  • Page 42 Cómo utilizar su unidad Luego de 15 minutos, mueva la palanca On/Auto/Off a la posición "OFF" y cierre Cómo detenerla: la válvula de drenaje (sentido horario). Coloque la posición de la llave Mueva la palanca On/Auto/Off a la interruptora On/Auto/Off en la posición "ON/AUTO".
  • Page 43: Mantenimiento

    MANTENIMIENTO Responsabilidades del cliente Antes Cada Diariamente Cada Anualmente o luego de cada horas cada uso horas Verifique la válvula de seguridad Drenaje del tanque Filtro de aire Válvulas de entrada y escape de la bomba del compresor de aire 1- Más frecuente en condiciones polvorientas o húmedas.
  • Page 44: Servicios Y Regulaciones

    Dentro del Si está sucio enjuague el filtro de aire tanque se con agua tibia y exprímalo hasta que producirá condensación de agua. Si no seque. drena, el agua lo corroerá y debilitará Vuelva a colocar el filtro de aire y su causando un riesgo de ruptura del cubierta.
  • Page 45: Servicio Y Ajustes

    SERVICIO Y AJUSTES La unidad cicla Tubo de Tuerca automáticamente salida en cuanto la energía eléctrica es conectada. Al efectuar el mantenimiento, Tubo aliviador Válvula usted quedará expuesto a tensión viva, de presión regula- aire comprimido o partes en movimiento. dora Debido a tales circunstancias, podrían ocurrirle lesiones personales.
  • Page 46: Almacenaje

    ALMACENAJE Antes de guardar el compresor de aire, Mientras levanta la lengüeta (A) rote asegurarse de hacer lo siguiente: el manillar (B) a su posición de almacenaje. Leer las secciones de "Mantenimiento" y Procedimiento para Operar en las páginas precedentes y hacer el mantenimiento según fuese necesario.
  • Page 47: Guía De Diagnóstico De Problemas

    GUÍA DE DIAGNÓSTICO DE PROBLEMAS El desarrollo de reparaciones puede exponer a sitios con corriente viva, partes en movimiento o fuentes de aire comprimido que podrían ocasionar lesiones personales. Antes de intentar reparación alguna, desenchufe el compresor de aire y purgue toda la presión de aire del tanque.
  • Page 48 PROBLEMA CAUSA CORRECCIÓN Si hubiese una caída excesiva Es normal que ocurra algún La lectura de la de presión durante el uso del descenso en la presión. presión sobre un accesorio, ajuste el regulador de manómetro (si acuerdo a las instrucciones de la viene equipado sección Operación.
  • Page 49 PROBLEMA CAUSA CORRECCIÓN El motor no Deje enfriar el motor y el El interruptor de protección des funciona. interruptor de sobrecarga se obrecarga del motor se ha reajustará automáticamente. abierto. El motor arrancará automáticamente La presión del tanque excede cuando la presión del tanque caiga la presión de "corte máximo"...
  • Page 50: Notes/Notas

    NOTES/NOTAS 50- SP A13570...
  • Page 51 Felicitaciones por hacer una compra ® ® Your new Craftsman product is designed and inteligente. Su nueva unidad Craftsman está manufactured for years of dependable operation. diseñada y fabricada para años de operación But like all products, it may require preventive confiable;...
  • Page 52 Get it fixed, at your home or ours! Your Home For repair – in your home – of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner’s manuals that you need to do-it-yourself.