Operation - Craftsman 919.152141 Owner's Manual

Permanently lubricated tank mounted air compressor
Table of Contents

Advertisement

E:_te_lsion
Cords
Using extension
cords
is not
recommended.
The use of extension
cords
will cause voltage
to drop
resulting
in power
loss to the motor
ang overheating.
Attacn
extra
air hoses at tt/e air outlet
instead
of us)rig
extension
cords.
If ar_ extension
cord
must
be used,
be
sure it is;
a 3-wire
extension
cord
that has
a 3-blade
grounding
plug, and a
3-stot
receptacle
that will accept
the plug on the product
In good
condition
no longer
than
50 feet
12 gauge
(AWG) or Jarger. (WJr_
_lze Jncrsases
as gauge
number
decreases.
10 AWG and 8 AWG
may also be used,
DO NOT USE
14 OR 16AWG)
Voltage
a[_d Circuii;
Protection
Refer to the Specification
Chart for
the voltage and minimum branch
circuit requirements.
Certain
airoompressor_
can be
operated
on a 15 amp
circuit
if the
following
conditions
are met.
1.
Voltage supply through branch
circuit is 15 crops.
2.
Circuit is not used to supply any
other electrical needs (lights,
appliances, etc.).
3.
E".xtertsion cords comply with
speciticatlons.
4.
Circuit is equipped with a 15
amp circuit breaker or 15 amp
tinle delay ruse. NOTE: tf
compressor is connected to a
circuit protected by fuses, u_e
only time delay fuses. Time delay
fuses should be marked "D" in
Canada and "T" in the US
If any of the above conditions cannot
be met, or if operation of the
compressor repeatedly causes
interruption of the power, it may be
necessary to operate it from a 20
amp circuit. It is not necessary to
change the cord set.
1t - ENG
D26336