General Instructions; Care Of Glass And Plated Parts - Napoleon Torch GSST8N Installation And Operation Instructions Manual

Table of Contents

Advertisement

4
THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local
codes. Installation practices vary from region to region and it is important to know the specifi cs that apply to your area,
for example: in Massachusetts State:
• The appliance off valve must be a "T" handle gas cock.
• The fl exible connector must not be longer than 36 inches.
• WARNING: This product must be installed by a licensed plumber or gas fi tter when installed within the commonwealth of
Massachusetts.
In absence of local codes, install to the current CAN/CGA -B149
Installation Code in Canada or to the National Fuel Gas Code, ANSI
Z223.1, and NFPA 54 in the United States.
The appliance and its individual shutoff valve must be disconnected from
the gas supply piping system during any pressure testing of that system
at test pressures in excess of 1/2 psig (3.5 kPa). The appliance must
be isolated from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig (3.5 kPa).
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY!
Altitude
Maximum Input
Minimum Inlet Gas Supply Pressure
Maximum Inlet Gas Supply Pressure
Manifold Pressure Under Flow Conditions
* When the appliance is installed at elevations above 4,500ft, and in the absence of specifi c recommendations from
the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for
each additional 1,000ft.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certifi ed kit is used.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
Purge all gas lines with the glass door of the appliance removed. Assure that a continuous gas fl ow is at the burner
before replacing the door.
Objects placed in front of the appliance must be kept a minimum of 48" from the front face of the unit.
Use only authorized accessories designed for and listed with the model.
The glass is 3/16" tempered glass, available from your
authorized dealer. Clean the glass after the fi rst 10 hours of
operation with a recommended gas appliance glass cleaner.
Thereafter clean as required. DO NOT CLEAN GLASS WHEN
HOT! Do not use abrasive cleaners to clean plated parts.
Buff lightly with a clean dry cloth. If the glass is not kept clean
permanent discolouration and / or blemishes may result.
W415-0689 / 06.25.08

GENERAL INSTRUCTIONS

GENERAL INFORMATION
RATES AND EFFICIENCIES

CARE OF GLASS AND PLATED PARTS

NATURAL GAS
0 - 4,500*
6,000
4.5" Water Column
7" Water Column
3.5" Water Column
WARNING
!
ALLOW CHILDREN TO TOUCH GLASS.
DO NOT SUBSTITUTE MATERIALS. USE CARE WHEN
HANDLING GLASS COMPONENTS. DO NOT STRIKE,
OR SLAM SHUT. DO NOT OPERATE WITH BROKEN
GLASS.
PROPANE GAS
0 - 4,500*
6,000
11" Water Column
13" Water Column
10" Water Column
HOT GLASS
WILL CAUSE BURNS.
DO NOT TOUCH
GLASS UNTIL COOLED.
NEVER

Advertisement

Table of Contents
loading

This manual is also suitable for:

Torch gsst8p

Table of Contents