Supplement for Embedded MegaRAID SATA User's Guide
CA97232-0014-01EN
Supplement for
Embedded MegaRAID SATA
User's Guide
1 / 13

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu Supplement for Embedded MegaRAID SATA

  • Page 1 Supplement for Embedded MegaRAID SATA User’s Guide CA97232-0014-01EN Supplement for Embedded MegaRAID SATA User’s Guide 1 / 13...
  • Page 2: Table Of Contents

    Supplement for Embedded MegaRAID SATA User’s Guide Contents Before reading this manual ................................3 About the change in the Array controller display name according to the driver's update........3 “Product Names” (page 3) ................................4 “2.1 SATA Setup Utility” (page 24) ............................4 “3.1 Updating Device Drives”...
  • Page 3: Before Reading This Manual

    ■ Information for PRIMERGY For the latest information on PRIMERGY, update modules, drivers and the software, refer to the Fujitsu PRIMERGY website. http://www.fujitsu.com/global/services/computing/server/ia/driver/ Regarding BIOS and FW, contact to Fujitsu Support Office. Refer to the website ( http://www.fujitsu.com/global/contact/computing/PRMRGY_index.html ■ Trademarks Microsoft, Windows and Windows Server are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries.
  • Page 4: Product Names

    Supplement for Embedded MegaRAID SATA User’s Guide “Product Names” (page 3) Include the following information when the “Table: Abbreviation of Product Names” on P.3 of the User’s Guide is referred. Table: Abbreviations of Product Names (addition) Product Names Description in the document Microsoft®...
  • Page 5: Updating Drivers (Windows Server 2008 - Full Installation)

    Supplement for Embedded MegaRAID SATA User’s Guide – – The update procedure for the device driver using Windows Server 2008 is as follows; Log on to Windows with Administrator privileges. Insert the “Array Controller Document & Tool CD” into a CD/DVD drive. Select [Diagnostics] ->...
  • Page 6: Updating Driver (Windows Server 2008 - Servercore Installation)

    Supplement for Embedded MegaRAID SATA User’s Guide – – Log on to Windows with Administrator privileges. Insert “Array Controller Document & Tool CD” into the CD/DVD drive. Execute the command below from the command prompt. ・For Windows Server 2008 pnputil -i -a [CD/DVD Drive]:\Drivers\MegaSR\W2K8\MegaSR.INF ・For Windows Server 2008 x64 pnputil -i -a [CD/DVD Drive]: \Drivers\MegaSR\W2K8x64\MegaSR.INF When device driver update is completed, remove the “Array Controller Document &...
  • Page 7: Access Privileges To Serverview Raid

    For Windows 2008 C:\Program Files\Fujitsu Siemens\RAID\web\public\ For Windows 2008 x64 C:\Program Files (x86)\Fujitsu Siemens\RAID\web\public\ “4.3.1 How to Install ServerView RAID” (page 65) “4.3.1 How to Install ServerView RAID” on page 65 is partially modified as follows; Step 3 Click the [Start] button – [Run...]. Enter the following path and click [OK].
  • Page 8: How To Uninstall Serverview Raid

    Supplement for Embedded MegaRAID SATA User’s Guide Step 6 Once the system is up and running, create and configure a Windows user account. Regarding the above, the description is change as follows; Current User’s Guide: (ServerView RAID V2.x.xx-x or previous) Users Account for User Privileges 1.
  • Page 9: Uninstallation Of Hdd Check Scheduler

    Supplement for Embedded MegaRAID SATA User’s Guide “4.4.4 Uninstallation of HDD Check Scheduler” (page 71) The procedure of the “4.4.4 Uninstallation of HDD Check Scheduler” on page 71 is partially modified as follows; Step 2 Click [Start] button – [All Programs] (or [Programs]) – [Accessories] – [Command Prompt].
  • Page 10: Viewing And Changing Array Controller Settings

    The table of the “POINT” on page 89 is partially modified as follows; Table: At the destination of event log files For Windows Server 2003 or C:\Program Files\Fujitsu Siemens\RAID\web\public\ Windows Server 2008 For Windows Server 2003 x64 or C:\Program Files (x86)\Fujitsu Siemens\RAID\web\public\ Windows Server 2008 x64 For Linux /opt/fsc/RAID/web/public 10 / 13...
  • Page 11: Checking Array Controller Status

    Supplement for Embedded MegaRAID SATA User’s Guide “4.9.2 Checking Array Controller Status” (page 98) When using driver version of V10.xx or later, As for “4.9.2 Checking Array Controller Status” on page 98, include the information as follows; Item Category Description BIOS version Version number of the expansion ROM BIOS for the array controller.
  • Page 12 Supplement for Embedded MegaRAID SATA User’s Guide Description Not detecting hard disks and unmatched insert locations The displayed message is different according to the situation. [Message 1] WARNING! BIOS detected configured disks w. some drive(s) missing, pls power off the system, remove the drive from port:XX and reinsert it in another slot.
  • Page 13 FUJITSU LIMITED ● The contents of this manual may be revised without prior notice. ● Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. ● No part of this manual may be reproduced in any form without the prior written permission of Fujitsu.