Digital x-ray pulse counter/timer
Hide thumbs Also See for Nuclear Associates 07-453:

Advertisement

Quick Links

Nuclear Associates 07-453
Digital X-Ray Pulse Counter/Timer
Operators Manual
February 2005
Manual No. 07-453-1 Rev. 2
©2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A.
All product names are trademarks of their respective companies

Advertisement

loading

Summary of Contents for Fluke Nuclear Associates 07-453

  • Page 1 Nuclear Associates 07-453 Digital X-Ray Pulse Counter/Timer Operators Manual February 2005 Manual No. 07-453-1 Rev. 2 ©2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies...
  • Page 2 Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland, Ohio 44139 440.498.2564 www.flukebiomedical.com/rms...
  • Page 3: Table Of Contents

    Table of Contents Section 1: General Information................... 1-1 Introduction ....................1-1 Description....................1-1 Specifications....................1-2 Battery Replacement ................... 1-2 Section 2: Operation....................2-1 General Instructions..................2-1 Oscilloscope Output..................2-2...
  • Page 4 (Blank Page)
  • Page 5: General Information

    General Information Introduction Section 1 General Information 1.1 Introduction The Model 07-453 Digital Pulse Counter measures exposure time for a wide variety of x-ray generators. For half-wave x-rays such as dental machines, the instrument is always used in Pulse mode. The instrument will display the number of pulses.
  • Page 6: Specifications

    The Digital X-Ray Pulse Counter/Timer is supplied with one 9 V alkaline battery. Replace the battery when the “Lo Batt” indicator shows in the display. Long life alkaline batteries are available from Fluke Biomedical. Any standard 9 V alkaline battery can be used in the Digital X-Ray Pulse Counter/Timer.
  • Page 7: Operation

    Operation General Instructions Section 2 Operation 2.1 General Instructions Switch Settings The front panel selector/toggle switch on the Digital X-Ray Pulse Counter/Timer has three positions: “OFF”, “PULSE” and “MILLISEC”. The switch is OFF when in the center position. All power to the instrument is disconnected in the “OFF” position. Set the switch to “OFF” when not in use, to conserve battery life.
  • Page 8: Oscilloscope Output

    1 V per cm. The scope waveform will be an amplified version of the actual output of the x-ray detector. A cable with a phone plug and a BNC connector for a scope is available from Fluke Biomedical (Model 88-453). The 2.5 mm mono phone plug is available from many vendors including Mouser Electronics, (P/N 177PP053).
  • Page 9 (Blank Page)
  • Page 10 Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland, Ohio 44139 440.498.2564 www.flukebiomedical.com/rms...