For Windows Nt 4. 0/Windows 98 - Oki B6250n Reference Manual

Reference guide
Hide thumbs Also See for B6250n:
Table of Contents

Advertisement

F
W
NT 4. 0/W
OR
INDOWS
When the printer is not printing
CAUSE
Incorrect IP address.
When [LPD Spool] is set
to [Memory], the print
data sent from a
computer in a single
print instruction has
exceeded the upper limit
of the receiving capacity.
An irrecoverable error
has occurred during
printing.
The transport protocol is
different from that of the
computer.
98/W
INDOWS
VERIFICATION
Ask your network
administrator to check
that the IP address is
correct.
Check the memory
capacity of [LPD Spool]
and compare it with the
print data which was
sent in the single print
instruction.
Check if an error is
displayed on the control
panel.
Check the selected
transport protocol.
B6250/B6500 User's Guide> 127
2000/W
INDOWS
ACTION
Specify the correct IP
address for the printer.
1. If a single file of print
data has exceeded the
upper limit of the
memory capacity, divide
the file into smaller ones
and try again.
2. If multiple files have
exceeded the upper limit
of memory capacity,
reduce the number of
files to be sent at one
time.
Switch off and then on
the printer.
Select the same
transport protocol as
that of the computer.
XP
INDOWS

Advertisement