Dimm Replacement Procedure; Installing The Dimm - Enterasys Platinum Distributed Forwarding Engine 7G4205-72 Hardware Installation Manual

Dfe-platinum series
Hide thumbs Also See for Enterasys Platinum Distributed Forwarding Engine 7G4205-72:
Table of Contents

Advertisement

Gaining Access to Memory Modules
4.
Reinstall the safety cover. Refer to "Reinstalling the Safety Cover" on page B‐14 for 
instructions.
Figure B-6
1 Connector arms
2 DIMM

DIMM Replacement Procedure

In the event that the DIMM needs to be replaced, the following sections explain how to 
remove and install the SIMM. If you have questions concerning the replacement of the 
SIMM, refer to "Getting Help"  on page xviii for details on how to contact 
Enterasys Networks.
Removing the DIMM
To remove the existing DIMM, proceed as follows:
1.
Remove and save the seven screws attaching the safety cover to the standoffs on the 
main PC board.
2.
Locate the DIMM connector on the main PC board. Refer back to Figure
DIMM location on the 7G4285‐49. 
B-10 Mode Switch Settings and Option Installations

Installing the DIMM

À
Caution: Observe all Electrostatic Discharge (ESD) precautions when handling sensitive
electronic equipment.
Precaución: Al trabajar con equipos electrónicos sensibles, tome todas las precauciones
de seguridad para evitar descargas de electricidad estática.
Ã
Á
Â
3 Connector fingers
4 DIMM alignment notches (2)
Ã
À
B‐2 for the 