  • Page 1 APOLLO 1U ICE 19" 1U Rack Mount Industrial Compact Enclosure Technical Manual...
  • Page 2 Definitions Eurotech is the trading name for Eurotech Ltd. Disclaimer The information in this manual has been carefully checked and is believed to be accurate. Eurotech assumes no responsibility for any infringements of patents or other rights of third parties, which may result from its use. Eurotech assumes no responsibility for any inaccuracies that may be contained in this document.
  • Page 3: Table Of Contents

    APOLLO 1U ICE Contents Contents About this manual ..........................4 Related documents ........................4 Conventions ...........................4 Introduction ............................5 APOLLO ICE specification.....................6 Using the enclosure safely.....................8 APOLLO 1U ICE ‘at a glance’....................9 Features of the APOLLO ICE....................10 Fan control ............................11 Connectors............................12 Internal configuration ........................20 Internal cable plan .......................21 PCI Card Module .........................22 Tamper detect switch ......................24...
  • Page 4: About This Manual

    APOLLO 1U ICE About this manual About this manual Related documents You can find further detailed information about the performance and operation of the APOLLO SBC in the APOLLO Technical Manual. Conventions The following symbols are used in this guide: Symbol Explanation Note - information that requires your attention.
  • Page 5: Introduction

    APOLLO 1U ICE Introduction Introduction The APOLLO 1U ICE system serves as a high performance, compact 19" rack mount ruggedized PC system for applications in IT systems, machine control, and kiosk solutions. The APOLLO 1U ICE is powered by a Celeron M/Pentium M based single board computer designed and manufactured by Eurotech Ltd.
  • Page 6: Apollo Ice Specification

    APOLLO 1U ICE Introduction APOLLO ICE specification The APOLLO ICE includes the following standard features: • 1U 19" standard ‘ruggedized’ enclosure. • Pentium M/Celeron M processor performance options. • Down to 600MHz Celeron M for fan-less systems. • Up to 2.1GHz Pentium M for server performance. •...
  • Page 7 APOLLO 1U ICE Introduction Factory build options available include: • Other CPU options with/without CPU fan available on request. Please contact our Sales team for price and availability - see Appendix A – Contacting Eurotech on page 32. • APOLLO motherboard fitted with Gigabit Ethernet option (providing 1x 10/100baseT and 1x 1000baseT ports).
  • Page 8: Using The Enclosure Safely

    APOLLO 1U ICE Introduction Using the enclosure safely Internal battery The APOLLO SBC is fitted with a 3V Lithium battery that is used to maintain the APOLLO’s real time clock and static RAM while the main supply is removed. The battery is fitted in a socket to allow easy replacement.
  • Page 9: Apollo 1U Ice 'At A Glance

    APOLLO 1U ICE Introduction APOLLO 1U ICE ‘at a glance’ Front panel view USB 2.0 x 2 Tamper detect User-defined label insert Navigation/Input on lid removal Firewire User LEDs On/Off HDD/CF card access Reset DVD/CDRW Rear panel views Wireless Parallel Antenna port Earth...
  • Page 10: Features Of The Apollo Ice

    APOLLO 1U ICE Introduction Features of the APOLLO ICE This 1U high 19" Rack Mount enclosure offers the following features: Front panel • On/Off momentary switch with integral power LED (blue). • Access hole to recessed reset switch. • HDD activity indicator. •...
  • Page 11: Fan Control

    APOLLO 1U ICE Fan control Fan control There are two fans on the APOLLO 1U ICE that can be controlled - the processor/CPU fan, and the system fan. (The fan in the PSU runs at a predetermined speed.) You can independently control the fan speed and preset using the BIOS screens. To do this, follow these steps: Press F2 during boot up and enter the BIOS setup facility.
  • Page 12: Connectors

    APOLLO 1U ICE Connectors Connectors The connectors on the APOLLO let you connect external devices such as keyboards, mouse devices, printers etc. Connector Function See … Audio Line Out. Page 13. Audio Line In. Page 13. Audio Mic In. Page 14. IEEE1394 port 0.
  • Page 13 APOLLO 1U ICE Connectors J1, J2, J3 – Audio connectors 3.5mm stereo audio jacks are used for audio connection. The audio codec can operate in either of the following modes: • 2.1 mode, which allows for microphone in, line in and line out operation. •...
  • Page 14 APOLLO 1U ICE Connectors J3 - 3.5mm audio jack PC99 Color: pink. Signal name 2.1 mode 5.1 mode Microphone In Surround centre Ring No Connect Low frequency effects Sleeve Ground Ground J4A – IEEE1394 connector port 0 6-pin IEEE1394 connector. Signal name +12V (Fused) Ground...
  • Page 15 APOLLO 1U ICE Connectors J5A – Primary LAN RJ-45 10/100Mb/s or optional 10/100/1000Mb/s. Signal name Signal name (10/100) (10/100/1000) MD0+ MD0- MD1+ No Connect MD2+ No Connect MD2- MD1- No Connect MD3+ No Connect MD3- For a Gigabit Ethernet (10/100/1000) connection the network cable should be a CAT5 or above and include all four pairs.
  • Page 16 APOLLO 1U ICE Connectors J6A – VGA CRT connector DB15 Female PC99 Color: Blue Signal name Signal name Green Blue No Connect Ground Ground Ground Ground +5V (Fused) Ground No Connect DDCSDA HSYNC VSYNC DDCSCL J6B – PS/2 keyboard Connector: 6-pin Mini-DIN PC99 Color: Purple Signal name KB DATA...
  • Page 17 APOLLO 1U ICE Connectors J6C – PS/2 mouse Connector: 6-pin Mini-DIN. PC99 Color: Green Signal name MS DATA No Connect Ground MS CLOCK No Connect © 2007 Eurotech Ltd Issue C...
  • Page 18 APOLLO 1U ICE Connectors J7A – Parallel port (LPT1) DB25 female PC99 Color: Maroon DB25 D-type socket Signal name STROBE ACKNOWLEDGE BUSY PAPER EMPTY SELECT AUTOFEED ERROR INIT SELECT IN Ground Ground Ground Ground Ground Ground Ground Ground © 2007 Eurotech Ltd Issue C...
  • Page 19 APOLLO 1U ICE Connectors J7B and J7C – COM1 and COM2 RS232 serial ports DB9 male PC99 Color: Aqua Signal name Signal name Data Carrier Receive Data (RX) Detect (DCD) Transmit Data Data Terminal (TX) Ready (DTR) Ground Data Set ready (DSR) Request To Send Clear To Send...
  • Page 20: Internal Configuration

    APOLLO 1U ICE Internal configuration Internal configuration Refer to Using the enclosure safely on page before proceeding any further. The internal components of the unit must only be accessed by suitably qualified personnel using anti-static equipment. The power supply must be switched off and the AC input cable unplugged.
  • Page 21: Internal Cable Plan

    APOLLO 1U ICE Internal configuration Internal cable plan PCI BAY APOLLO SBC Flexible PCI Riser Tamper Detect Firewire DRIVE BAY FRONT PANEL APOLLO ICE FPI BOARD BREAKOUT MODULE For clarity, power cables are not shown. © 2007 Eurotech Ltd Issue C...
  • Page 22: Pci Card Module

    APOLLO 1U ICE Internal configuration PCI Card Module This section explains how to remove the PCI Module and fit a PCI card. The components described in the procedures that follow are illustrated by the following diagram: PCI Riser Tamper detect Slots in (Flex to APOLLO micro switch...
  • Page 23 APOLLO 1U ICE Internal configuration Remove any cables attached to installed PCI expansion cards before attempting removal of the PCI module. To remove the PCI Module, follow these steps: Unplug the flexible riser connection to the APOLLO SBC. Take care to pull on the plug-in connector rather than the flexible cable. Disconnect the tamper detect cable from front panel breakout board assembly.
  • Page 24: Tamper Detect Switch

    APOLLO 1U ICE Internal configuration Tamper detect switch The tamper detect feature is triggered by the opening and closing of the lid. It is affected by a switch mounted on the PCI module: Tamper detect switch A tamper detection input is included within the real time clock circuitry of the APOLLO that operates in all power modes.
  • Page 25: User Status/Display And Navigation Buttons

    APOLLO 1U ICE Internal configuration User status/display and navigation buttons The LCD offers 2 x 24 character visibility with white lettering on an illuminated blue background. The Front Panel Interface enables connection to the front navigation/input switches and the three user-defined LEDs. The LCD and Front Panel Interface are shown in the following photograph: LED ident strip The Front Panel Interface is ‘stacked’...
  • Page 26 APOLLO 1U ICE Internal configuration The following images illustrate how you insert the LED ident strip: The LED ident strip can be reversed for writing legends, or discarded and a printed card inserted in the open slot. Control of the character display, LEDs and navigation keys is implemented using drivers supplied by Eurotech Ltd.
  • Page 27: Front Panel Breakout Module

    APOLLO 1U ICE Internal configuration Front panel breakout module Eurotech Ltd ref. 6060-0709-001-102. The front panel breakout module assembly is shown in the following photograph: Features • On/off momentary switch with integral blue LED. • Reset switch. • HDD/CF card activity indicator LED. •...
  • Page 28 APOLLO 1U ICE Internal configuration Pin settings The following pin settings are as viewed looking at the front panel: USB 2.0 Signal VBUS Data- Data+ Ground Firewire Signal +12V Ground TPB0- TPB0+ TPA0- TPA0+ © 2007 Eurotech Ltd Issue C...
  • Page 29: Drive Bay Module

    APOLLO 1U ICE Internal configuration Drive Bay Module The drive bay module features: • Slimline slot loading DVD/CDRW (Primary Slave). • 1.44MB floppy disk drive. • Slimline 40GB 2.5" hard disk drive (Master). • CD/DVD adapter pcb. It is shown in the following photographs: CD/DVD adapter pcb To remove the drive bay module, follow these steps: Unplug the FDD flat flexible connection to the APOLLO SBC, the IDE connection...
  • Page 30: Dimension Details

    APOLLO 1U ICE Internal configuration Dimension details The unit complies with standard (IEC 60297 and IEC 60917) 19" Rack Mounting dimensions and will fit into a standard rack cabinet. The rack mount brackets can be adjusted in order to recess front panel features (i.e. to ensure connectors clear cabinet doors etc.).
  • Page 31: Weight Details

    APOLLO 1U ICE Internal configuration Weight details The weight of the unit depends on the configuration used and the optional items chosen when ordering, the unit nominal weight is approximately 6.0kg (13.20lbs). © 2007 Eurotech Ltd Issue C...
  • Page 32: Appendix A - Contacting Eurotech

    APOLLO 1U ICE Appendix A – Contacting Eurotech Appendix A – Contacting Eurotech Eurotech sales Eurotech’s sales team is always available to assist you in choosing the board that best meets your requirements. Eurotech Ltd 3 Clifton Court Cambridge CB1 7BN Tel: +44 (0)1223 403410 Fax:...
  • Page 33: Appendix B - Optional Add (Agp Digital Display) Graphics Cards

    APOLLO 1U ICE Appendix B - Optional ADD (AGP Digital Display) graphics cards Appendix B - Optional ADD (AGP Digital Display) graphics cards The APOLLO can drive the Digital Video Output (DVO) port of the Intel Extreme 2 Graphics Controller to connector J16. This provides a means for adding an extra graphics port to the APOLLO.
  • Page 34: Apollo-Usb-Dvo: Vga

    APOLLO 1U ICE Appendix B - Optional ADD (AGP Digital Display) graphics cards APOLLO-USB-DVO: VGA The VGA Card converts APOLLO high-resolution DVO (digital video output) to analog CRT outputs, from VGA to SXGA resolutions. The following image shows the VGA card in position: Features •...
  • Page 35: Appendix C - Emc Conformity

    APOLLO 1U ICE Appendix C – EMC conformity Appendix C – EMC conformity The European Directive 89/336/EEC, on Electro-magnetic Compatibility (EMC), requires that, generated electro-magnetic disturbance must, be in accordance with European Harmonized Standards, for Electro-Magnetic Emissions and Immunity. Generic Emissions and Immunity Standards Emissions: EN55022:1998, A1, A2 •...
  • Page 36: Index

    APOLLO 1U ICE Index Index ADD card · 10 fan · 10 antenna, wireless · 10 fan-less systems · 6 anti-static · 8 FDD · 6, 10 audio · 10, 13 features · 5, 10 optional · 5, 7, 33 Firewire ·...
  • Page 37 APOLLO 1U ICE Index rear panel · 10 reset switch · 10, 27 primary · 15 secondary · 15 LCD · 5, 6, 10, 25 LEDs · 10 secondary LAN · 15 LPT1 · 18 secure applications · 5 secure systems · 5 serial ports ·...

Table of Contents