GAS
ROUGH-IN
Check local codes t\_rrequirements as to the size and type of
gas line required. See Figure 5 for location of gas inlet holes
in furnace cabinet.
Compounds used on threaded joints of gas pipe should be
resistant to the action of liquefied petroleum gases. The gas
line joints must be checked t\_r leaks. This should be done
with a soap solution
watching
for bubbles
on all
connections.
NEVER USE AN EXPOSED
FLAME TO
CHECK FOR LEAKS.
A manual valve equipped with a 1/8" NPT plugged tapping
accessible
for test gauge connection
should be installed
immediately upstream of the gas supply connection to the
appliance.
Some codes and ordinances
require that the
manual valve be located outside the appliance.
See Figure
4.
The appliance
and its individual
shut off valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
V2psig.
The appliance must be isolated from the gas supply piping
system by closing its individual manual shut offvalve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ pig.
It is required by the National Fuel Gas Code that a drip line
be installed near the gas inlet. This should consist of a vertical
length of pipe tee connected into the gas line that is capped
on the bottom in which condensation and foreigu particles
may collect.
Gas
Supply
Lin__j
Manual j_v_
1/8 N.P.T.
cut off
Pressure Tap
valve
FIGURE 4
FIGURE 5
Page 7