Controller Properties Menu Options (Cont.)
Option
Patrol Read
Rate
Cache Flush
Interval
Spinup Drive
Count
Spinup Delay
Stop CC on
Error
Maintain PD
Fail History
Controller BIOS
Link Speed
Schedule CC
StopOnError
Disk Activity
If you make changes to the options on this screen, click Submit to register them. If
you change your mind, click Reset to return the options to their default values.
2-32
Description
Use this option to select the rate for patrol reads for drives connected to
the selected controller. The default is 30 percent. The patrol read rate is
the percentage of system resources dedicated to running a patrol read.
Use this option to control the interval (in seconds) at which the contents
of the onboard data cache are flushed. The default is 4 seconds.
Use this option to control the number of drives that spin up
simultaneously. The default is 4 drives.
Use this option to control the interval (in seconds) between spinup of
drives connected to this controller. The delay prevents a drain on the
system's power supply that would occur if all drives spun up at the
same time. The default is 12 seconds.
Use this option if you want to stop a consistency check when the
controller BIOS encounters an error. The default is No.
Use this option to maintain the history of all drive failures. The default
is Enabled.
Use this option to enable or disable the BIOS for the selected controller.
The default is Enabled. If the boot device is on the selected controller,
the BIOS must be enabled. Otherwise, the BIOS should be disabled or
it might not be possible to use a boot device elsewhere.
Use this option to change the link speed between the controller and
an expander or between the controller and a drive that is directly
connected to the controller.
"Supported" will be displayed if the controller supports consistency
check schedule.
Enable this option if you want the boot process to stop when the
controller BIOS encounters an error during boot-up. The default is
Enabled.
Enable this option if you want to locate a particular disk. This disk can
be identified with a continuous blinking of green activity LED. This
works only if the disks are installed in an enclosure. The default is
Disabled.