PLC-XC56 Expand Serial Command Functional Specifications
8.4.5
CF_SHARP Command
Command
"CF_SHARP_%1"[CR]
"000~015" ---------------- Directly select Sharpness setting value
%1
"UP" ------------------------ Current Sharpness setting value + 1
"DN" ------------------------ Current Sharpness setting value - 1
Set Sharpness value of user control
Projector does not save the value set with this command so that it returns its
Details
original when projector turning into Stanby mode or ALL is OFF. (The value is held
in Suspend mode.)
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.4.6
CF_GAMMA Command
Command
"CF_GAMMA_%1"[CR]
"000~015" ---------------- Directly set Gamma setting value
%1
"UP" ------------------------ Current Gamma setting value + 1
"DN" ------------------------ Current Gamma setting value – 1
Set Gamma value of user control
Projector does not save the value set with this command so that it returns its
Details
original when projector turning into Stanby mode or ALL is OFF. (The value is held
in Suspend mode.)
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.4.7
CF_WBAL - Command
Command
"CF_WBAL-%1_%2"[CR]
"ÿ 2 " --------------------- Red
%1
"ÿ ' " --------------------- Green
"ÿ " " --------------------- Blue
"000~063" ----------- Directly select Color value specified by White Balance%1
%2
"UP" ------------------- Current Color value set by White Balance%1 + 1
"DN" ------------------- Current Color value set by White Balance%1 - 1
Set Color value set by White Balance%1 of user control
Projector does not save the value set with this command so that it returns its
Details
original when projector turning into Stanby mode or ALL is OFF. (The value is held
in Suspend mode.)
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
16 / 65