Performance At Other Environmental Conditions - Energizer PP355 Handbook

Energizer battery handbook
Table of Contents

Advertisement

 
Figure 7:  Comparison of Performance under Continuous Constant Power 
 
 
 
2.2 ‐‐ Performance at Other Environmental Conditions 
 
When a Zinc Air battery is exposed to a non‐standard environment, a driving force for water transport in 
or out of the battery exists.  Movement of water vapor into the battery can fill void space in the anode 
cavity under high humidity environments, and movement of water vapor out of the battery can dry out 
the electrolyte in low humidity environments.  Either situation can decrease battery performance over 
time.   
 
Understanding  the  environmental  conditions  that  a  battery  might  encounter  is  critical  to  estimating 
battery  performance.    A  study  was  done  at  Energizer  to  determine  realistic  extreme  conditions  for 
battery  testing,  using  climate  data  from  61  cities  across  the  globe.    These  cities  represent  the  major 
markets for both devices and batteries.  Combinations of daily morning and afternoon temperature and 
humidity were compiled and analyzed to determine reasonable temperature and humidity extremes. 
 
Hot and Humid Conditions:   
Zinc Air Prismatic batteries can take on water when exposed to hot and humid conditions.  This can limit 
battery  performance  by  taking  up  void  volume  in  the  air  electrode  and  anode  compartment.    At  35°C 
and  75%  RH  conditions,  there  is  a  driving  force  for  water  gain  larger  than  99%  of  conditions  seen  in 
combined indoor and outdoor data from the top 61 cities globally.  Service tests with the PP355 under 
these conditions show very good service even at 1 hr per day intermittency. 
 
Hot and Arid Conditions: 
Zinc  Air  Prismatic  batteries  can  lose  water  when  exposed  to  hot  and  arid  conditions  which  can  limit 
battery performance by drying out the battery.  Under 35°C and 25% RH conditions, there is a driving 
force for water loss larger than 99% of conditions seen in combined indoor and outdoor data from the 
top 61 cities globally.  Service testing with the PP355 at these conditions shows very good service even 
at 1 hr per day intermittency. 
 
 
Continuous Discharge Time (hrs)
AAAA
25 mW
24
50 mW
11
75 mW
6
100 mW
4
ENERGIZER BATTERY MANUFACTURING 
VERSION 1.2 
PP355
88
38
24
15
 
P a g e
 | 8 