Figure 11:  Overview of Different Air Management Techniques  
high 
low 
 
3.2 ‐‐ Elements of Air Management 
 
Two elements of a successful in‐device air management system are a means for allowing controlled air 
access to the battery and an air plenum for even air distribution.  An air plenum is an air gap, or volume, 
which  has  access  to  all  of  the  air  holes  on  the  battery.    The  air  plenum  allows  for  more  even  air 
distribution  over  the  battery  air  holes,  and  it  provides  a  reserve  of  air  immediately  available  to  the 
battery to handle peak power needs.  Controlling air access to the battery is accomplished by creating an 
access  path  to  the  sealed  volume  of  air  within  a  device.    The  air  access  path  is  designed  to  allow  a 
desired  amount  of  air  to  flow  to  the  sealed  volume  of  air,  which  includes  the  plenum,  either 
continuously  or  intermittently.    A  sealed  volume  of  air  can  be  created  by  sealing  an  entire  device,  a 
portion of the device including the battery compartment, or just a plenum above the air hole side of the 
battery.  The power requirements of the device determine the rate at which air is required to flow to the 
battery.  
 
Figure  12  illustrates  a  simple,  cost  effective  air  management  solution  designed  into  a  device.    The 
compartment door contains an o‐ring which seals against the air hole side of the battery when the door 
is closed.  The air plenum volume is defined by  the compartment door and the sides of the o‐ring.  A 
slide switch is located in the compartment door to create an air access point.  The slide switch acts as a 
valve  which  seals  the  compartment  when  in  the  closed  position  and  allows  air  to  flow  to  the  battery 
when  in  the  open  position.    The  slide  switch  could  be  mechanically  manipulated  by  the  user  or 
electronically controlled by the device. 
high degree of air management needed, 
none or small 
cell has high air access but is expected to 
degree of air 
be in service with long periods of "off" 
management 
needed, since cell 
capacity is quickly 
used
(1‐3 months)
throttling needed to 
maximize service 
time  (>3 months)
continuous
Duty Cycle
ENERGIZER BATTERY MANUFACTURING 
VERSION 1.2 
time (>3 months)
intermittent
P a g e
 | 13 
 