Download Print this page
Energizer E95 Product Data Sheet

Energizer E95 Product Data Sheet

Energizer battery data sheet

Advertisement

Quick Links

PRODUCT DATASHEET
ENERGIZER E95
Industry Standard Dimensions
(millimeters)
9.50
Maximum
18.00
Minimum
Industry Standard Testing (21°C):
10 ohm 4 hrs/day
1.6
1.4
1.2
1.0
0.8
0
30
60
Service (hours)
TOY
2.2 ohm 1 hr/day
1.6
1.4
1.2
1.0
0.8
0
6
12
Service (hours)
This datasheet contains typical information specific to products manufactured at the time of its publication.
m No. EBC - 8908AP
34.20
32.30
1.50
Minimum
61.50
59.50
RADIO
90
120
150
LIGHTING
2.2 ohm LIF
LIF
TOY
18
24
30
Important Notice
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.

Specifications

Classification:
Alkaline
Chemical System:
Zinc-Manganese Dioxide (Zn/MnO
No added mercury or cadmium
Designation:
IEC-LR20
Nominal Voltage:
1.5 volts
Nominal IR:
150 to 300 milliohms (fresh)*
Operating Temp:
-18°C to 55°C
Typical Weight:
148.0 grams
Typical Volume:
56.0 cubic centimeters
Jacket:
Plastic Label
Shelf Life:
7 years at 21°C (80% of initial capacity)
Terminal:
Flat Contact
* For additional information, please reference the
Milliamp-Hours Capacity
Continuous discharge to 0.8 volts at 21°C
24000
18000
12000
6000
0
25
Discharge (mA)
Battery Selection Indicator
Asia Pacific Region
1-800-383-7323 / USA
1-800-383-7323 / CANADA
+852‐31026623
D
)
2
IR technical white
paper.
100
250
500
High Drain
Devices
Moderate Drain
Devices
Low Drain
Devices
Page 1 of 1